background image

 www.e-t-a.de

Electronic Circuit Protector ESX10-T.-DC 24 V

1822

15

  4

ESX10-T.-DC 24 V -

 

Accessories / Installations guidelines and safety instructions

All information and data given on our products are accurate and reliable to the best of our 
knowledge, but E-T-A does not accept any responsibility for the use in applications which are 
not in accordance with the present specification. E-T-A reserves the right to change specifi-
cations at any time in the interest of improved design, performance and cost effectiveness, 
Dimensions are subject to change  without notice. Please enquire for the latest dimensional 
drawing with tolerances if required. All dimensions, data, pictures and descriptions are for 
information only and are not binding. Amendments, errors and omissions excepted. Ordering 
codes of the products may differ from their marking.

Accessories

ESX10-TD-. Application example of adhesive label

switch for 

current rating

adjustment

cover label

with adjusted rating, e.g. 4 A

see accessories

ESX10-TD-...
cover for current rating adjustment

xx   xx

2 A
4 A
6 A

ok

on

r

e

s

e

t

off

2 LOAD+

xx   xx

ok

on

r

e

s

e

t

off

2 LOAD+

4 A

Labels, pack of 10

suitable for ESX10-TD, cover of current rating adjustment

Y 309 705 11 (0.5 A, 1 A, 2 A)

Y 309 705 12 (2 A, 4 A, 6 A)

Y 309 705 13 (6 A, 8 A, 10 A)

Y 309 705 14 (2 A, 3 A, 4 A)

Labels, pack of 30

suitable for ESX10-TD , cover of current rating adjustment
Y 309 705 21 (0.5 A)
Y 309 705 22 (1 A)
Y 309 705 23 (2 A)
Y 309 705 24 (3 A)
Y 309 705 25 (4 A)
Y 309 705 26 (6 A)
Y 309 705 27 (8 A)
Y 309 705 28 (10 A)

2 A

4 A

6 A

 
  Passive supply moudle for for LINE+ and 0 V 
  (without protection)

  Ampacity 

 

  

I

max

 

50 A

  Max. cable cross section see ESX10-T

  part no. AD-TX-EM01

max. 50 

A

LINE+ 

1

0V 

3

Supply Module

AD-TX-EM01

DC 24 

V

Made in Germany

AD-TX-

EM01

GERMAN

Y

Содержание ESX10-T -DC Series

Страница 1: ...on l Capacitive loads up to 75 000 F l ESX10 TA TB fixed current ratings 0 5 A 12 A l ESX10 TD adjustable current ratings e g 0 5 A 1 A 2 A 2 A 4 A 6 A 6 A 8 A 10 A l Approvals UL CSA GL l OPTION Cont...

Страница 2: ...ntrol signal OFF device is switched off l No operating voltage UB Reset input RE ESX10 T 124 127 Electrical data voltage max DC 32 V High DC 8 V DC 32 V Low DC 3 V 0 V current consumption typically 2...

Страница 3: ...pping length 10 mm tightening torque EN60934 1 5 1 8 Nm multi lead connection 2 identical cables rigid flexible 0 5 4 mm2 flexible with wire end ferrule without plastic sleeve 0 5 2 5 mm2 flexible wit...

Страница 4: ...l output only ESX10 TA 1 signal make contact 2 signal break contact 4 status output SF only 114 124 7 status output inverted only ESX10 T 127 Operating voltage DC 24 V voltage rating DC 24 V Current r...

Страница 5: ...0 mV 1 8 x IN 1 A 1 A 1 A 2 A 130 mV 1 8 x IN 2 A 2 A 2 A 3 A 80 mV 1 8 x IN 3 A 3 A 3 A 4 A 100 mV 1 8 x IN 4 A 4 A 4 A 6 A 130 mV 1 8 x IN 6 A 6 A 6 A 8 A 120 mV 1 5 x IN 8 A 8 A 8 A 10 A 150 mV 1 5...

Страница 6: ...DC 24 V 0 5 A 16 A UL ISA 12 12 01 2015 Class Division 2 Groups A B C D E320024 DC 24 V 0 5 A 12 A UL UL 508 C22 2 No 14 E322549 DC 24 V 0 5 A 16 A DNV GL Rules VI part 7 GL 2012 category C EMC1 4676...

Страница 7: ...lymers Corporation Type Epi Fine 4616L 160PK Casing Material Generic Name Liquid Crystal Polymer Supplier Sumitomo Chemical Type E4008 E4009 or E6008 RECOMMENDATION Periodically inspect the device nam...

Страница 8: ...erating condition SF 24 V OK fault condition SF 0 V LINE 1 14 13 2 LOAD 0V 3 ESX10 TB 101 without signal input with signal output F single signal N O operating condition 13 14 closed fault condition 1...

Страница 9: ...on ESX10 T and tolerance of the shut off point typically 1 1 x IN 1 05 1 35 x IN has already been taken into account ESX10 T current rating adjustment IN in A e g trip current Iab 1 25 x IN in A Rmax...

Страница 10: ...13 grey remove protection against brush contact from bottom side 12 5 x n 3 length of busbars 0 5 e g 12 5 x 5 3 59 5 0 5 insert protection against brush contact continuous busbar 500 mm length cut 5...

Страница 11: ...3 0V 2 LOAD 2 LOAD 2 LOAD Connection diagrams and application examples ESX10 T Signal contacts are shown in OFF or fault condition ESX10 TA 100 ESX10 TB 101 group signalling series connection line en...

Страница 12: ...2 or X 222 611 xx LINE busbar X 222 611 02 or X 222 611 xx single signalling per way by means of an LED 22 1 LINE RE SF 23 22 1 LINE RE SF 23 22 1 LINE RE SF 23 reset button power supply DC 24 V 24 V...

Страница 13: ...mp 0 V busbar X 222 611 02 or X 222 611 xx power supply DC 24 V 24 V 0 V line entry 0 5 A ESX10 TA 100 1 LINE 1 LINE 1 LINE 1 LINE 2 LOAD 2 LOAD 2 LOAD 2 LOAD 11 11 11 12 12 12 line entry ESX10 TB 102...

Страница 14: ...for aux contacts and reset inputs suitable for signal busbars ESX10 TB ampacity with one input Imax 1 A with aux contacts connected in series Imax 0 5 A grey insulated length 500 mm part no X 222 005...

Страница 15: ...from their marking Accessories ESX10 TD Application example of adhesive label switch for current rating adjustment cover label with adjusted rating e g 4 A see accessories ESX10 TD cover for current...

Отзывы: