Electronic Circuit Protector ESX10-T.-DC 24 V

1822

5

  4

Electronic Circuit Protector ESX10-T.-DC 24 V

Table 2: ESX10-T – product versions 

Version

Signal input

Signal output

Signal output F (signal contact)

Status output SF

ESX10-..

w/o

control input

ON/OFF +24 V

Control IN+

reset input

+24 V 

RE

w/o

single signal

make contact

(normally 

open NO)

single signal

break  

contact

(normally 

closed NC)

w/o

status OUT

+24 V = OK

status OUT

0 V = OK

-TA 

-100

x

x

x

-TB/-TD

-101

x

x

x

-TB/-TD

-102

x

x

x

-TB/-TD

-114

x

x

-TB/-TD

-124

x

x

x

-TB/-TD

-127

x

x

x

Connection diagram ESX10-TB-6A (example)

Elect

ro

nic Cir

cuit Pr

otector

ESX10-TB-101-DC24V

-6A

13

14

GERMANY

TB-101

13

14

ok

r

e

s

e

t

on

off

6A

2 LOAD+

LINE+

1

14

13

2

LOAD+

0V

3

Table 1: Voltage drop, current limitation, max. load current

current 
rating I

N

typical 
voltage 
drop
U

ON

 at I

N

active 
current 
limitation 
I

Limit 

(typ-

ically)

max. load current at 100% ON 
duty, U

B

 DC 24 V

T

amb

 = 40 °C         T

U

 = 50 °C         

T

amb

 = 60 °C

0.5 A

70 mV

1,8 x IN

0.5 A

0.5 A

0.5 A

1 A

80 mV

1,8 x IN

1 A

1 A

1 A

2 A

130 mV

1,8 x IN

2 A

2 A

2 A

3 A

80 mV

1,8 x IN

3 A

3 A

3 A

4 A

100 mV

1,8 x IN

4 A

4 A

4 A

6 A

130 mV

1,8 x IN

6 A

6 A

6 A

8 A

120 mV

1,5 x IN

8 A

8 A

8 A

10 A

150 mV

1.5 x IN

10 A

10 A

9.8 A

12 A

180 mV

1.3 x IN

12 A

11 A

9.8 A

[0.5/1/2 

A]

70/80/ 

130 mV

1.4 x IN

0,5/1/2 A

0,5/1/2 A

0.5A/1A/2A

[2/3/4 A]

130/80/ 
100 mV

1.4 x IN

2/3/4 A

2/3/4 A

2A/3A/4A

[2/4/6 A]

130/100/ 

130 mV

1.4 x IN

2/4/6 A

2/4/6 A

2A/4A/6A

[6/8/10 

A]

130/120/ 

150 mV

1.4 x IN

6/8/10 A

6/8/10 A

6A/8A/9.8A

Note: 
When mounted side-by-side without convection, the devices can 
only carry max. 80 % of their rated current continuously (100 % ON 
duty) due to the thermal effect.

Notes

l  

The user has to ensure that the cable cross section of the load 
circuit in question complies with the current rating of the ESX10-T 
used.

l  

In addition special precautions have to be taken in the system or 
machinery to exclude automatic re-start (e.g. by using a safety PLC) 
(cf. Machinery Directive 2006/42/EG und EN 60204-1, Safety of 
Machinery). In the event of a failure (short circuit/overload) the load 
circuit will be disconnected electronically by the ESX10-T. 

Содержание ESX10-T -DC Series

Страница 1: ...on l Capacitive loads up to 75 000 F l ESX10 TA TB fixed current ratings 0 5 A 12 A l ESX10 TD adjustable current ratings e g 0 5 A 1 A 2 A 2 A 4 A 6 A 6 A 8 A 10 A l Approvals UL CSA GL l OPTION Cont...

Страница 2: ...ntrol signal OFF device is switched off l No operating voltage UB Reset input RE ESX10 T 124 127 Electrical data voltage max DC 32 V High DC 8 V DC 32 V Low DC 3 V 0 V current consumption typically 2...

Страница 3: ...pping length 10 mm tightening torque EN60934 1 5 1 8 Nm multi lead connection 2 identical cables rigid flexible 0 5 4 mm2 flexible with wire end ferrule without plastic sleeve 0 5 2 5 mm2 flexible wit...

Страница 4: ...l output only ESX10 TA 1 signal make contact 2 signal break contact 4 status output SF only 114 124 7 status output inverted only ESX10 T 127 Operating voltage DC 24 V voltage rating DC 24 V Current r...

Страница 5: ...0 mV 1 8 x IN 1 A 1 A 1 A 2 A 130 mV 1 8 x IN 2 A 2 A 2 A 3 A 80 mV 1 8 x IN 3 A 3 A 3 A 4 A 100 mV 1 8 x IN 4 A 4 A 4 A 6 A 130 mV 1 8 x IN 6 A 6 A 6 A 8 A 120 mV 1 5 x IN 8 A 8 A 8 A 10 A 150 mV 1 5...

Страница 6: ...DC 24 V 0 5 A 16 A UL ISA 12 12 01 2015 Class Division 2 Groups A B C D E320024 DC 24 V 0 5 A 12 A UL UL 508 C22 2 No 14 E322549 DC 24 V 0 5 A 16 A DNV GL Rules VI part 7 GL 2012 category C EMC1 4676...

Страница 7: ...lymers Corporation Type Epi Fine 4616L 160PK Casing Material Generic Name Liquid Crystal Polymer Supplier Sumitomo Chemical Type E4008 E4009 or E6008 RECOMMENDATION Periodically inspect the device nam...

Страница 8: ...erating condition SF 24 V OK fault condition SF 0 V LINE 1 14 13 2 LOAD 0V 3 ESX10 TB 101 without signal input with signal output F single signal N O operating condition 13 14 closed fault condition 1...

Страница 9: ...on ESX10 T and tolerance of the shut off point typically 1 1 x IN 1 05 1 35 x IN has already been taken into account ESX10 T current rating adjustment IN in A e g trip current Iab 1 25 x IN in A Rmax...

Страница 10: ...13 grey remove protection against brush contact from bottom side 12 5 x n 3 length of busbars 0 5 e g 12 5 x 5 3 59 5 0 5 insert protection against brush contact continuous busbar 500 mm length cut 5...

Страница 11: ...3 0V 2 LOAD 2 LOAD 2 LOAD Connection diagrams and application examples ESX10 T Signal contacts are shown in OFF or fault condition ESX10 TA 100 ESX10 TB 101 group signalling series connection line en...

Страница 12: ...2 or X 222 611 xx LINE busbar X 222 611 02 or X 222 611 xx single signalling per way by means of an LED 22 1 LINE RE SF 23 22 1 LINE RE SF 23 22 1 LINE RE SF 23 reset button power supply DC 24 V 24 V...

Страница 13: ...mp 0 V busbar X 222 611 02 or X 222 611 xx power supply DC 24 V 24 V 0 V line entry 0 5 A ESX10 TA 100 1 LINE 1 LINE 1 LINE 1 LINE 2 LOAD 2 LOAD 2 LOAD 2 LOAD 11 11 11 12 12 12 line entry ESX10 TB 102...

Страница 14: ...for aux contacts and reset inputs suitable for signal busbars ESX10 TB ampacity with one input Imax 1 A with aux contacts connected in series Imax 0 5 A grey insulated length 500 mm part no X 222 005...

Страница 15: ...from their marking Accessories ESX10 TD Application example of adhesive label switch for current rating adjustment cover label with adjusted rating e g 4 A see accessories ESX10 TD cover for current...

Отзывы: