background image

 

 

2. GENERAL DESCRIPTION 

 

CPC12 - transparency through webserver and 
fieldbus connection 

 
The requirements of machine and plant construction 
regarding machine uptime and a consistently high 
production quality are increasing. Stable processes 
are based on a reliable and transparent DC24V pro-
tection and power distribution system. 

E-T-A’s CPC12 bus controller has a separate DC24V 
power supply and allows independent supply of the 
circuit protectors. It records all status information and 
measuring values. These data are visualised with the 
internal webserver. Via the field bus interface, the 
data are also made available to the superordinate 
control systems. 

 

 

 

 

 

E-T-A’s 

REX12D system in combination with the 

CPC12 bus controller

 was designed specifically for 

the requirements of the machine construction and 
process control industry. The REX12D modular 
power distribution system combined with the CPC12 
bus controller meets all requirements. 

 

• 

Maximises plant and machine uptime

 

through clear failure detection, high 
transparency and remote diagnosis 

• 

Saves space

 through a slim design of 

the circuit protectors and the potential 
modules 

• 

Increases flexibility of system plan-
ning

 through many different modules 

meeting the demands of DC24V power 
distribution 

 

 

Image 1: CPC12 bus controller as intelligent power distribution system 

Содержание ControlPlex CPC12

Страница 1: ...1 20 INSTRUCTION MANUAL INSTRUCTION MANUAL ControlPlex CPC12 bus controller Webserver...

Страница 2: ...Connection with the Webserver 6 4 Webserver Functionality 9 4 1 Menu Bar 9 4 1 1 User Management 9 4 1 2 CPC Info 10 4 1 3 Configure 10 4 1 4 Commands 14 4 2 Status Bar 16 5 Circuit Breaker Overview 1...

Страница 3: ...e Qualified personnel This user manual must exclusively be used by quali fied personnel who are able based on their training and experience to realise arising problems when handling the product and to...

Страница 4: ...the field bus interface the data are also made available to the superordinate control systems E T A s REX12D system in combination with the CPC12 bus controller was designed specifically for the requ...

Страница 5: ...5 5 Image 2 Setup of the REX12D system in combination with the CPC12 bus controller...

Страница 6: ...set to the standard IP range 192 168 1 XXX for example 192 168 1 254 1 Under Windows Settings the submenu Network and Internet is selected 2 Clicking on Change adapter options opens the Network conne...

Страница 7: ...Edge browser was used In addition the browser variants Chrome and Mozilla Firefox in the latest versions are possible Only these variants are checked and available for the webserver All other browser...

Страница 8: ...8 After a successful connection the following overview page of the ControlPlex system is displayed Image 7 Overview page of the ControlPlex system...

Страница 9: ...management Depending on the selection of a function a pop up window appears with the request to enter the username and password the ControlPlex system In addition an overview of the supply voltage and...

Страница 10: ...on No admin rights needed The product ID the serial number as well as the hardware and software version are displayed This in turn includes various functionalities which are described below 4 1 3 2 Ne...

Страница 11: ...e language setting is also reset to English and the user management is reset The function is only possible in Admin mode 4 1 3 4 Edit Users After selecting the function a new window opens with the ove...

Страница 12: ...e Update After selecting the Firmware Update function an Explorer window opens to access the location of the firmware file The latest firmware updates are availa ble in the download portal of the Cont...

Страница 13: ...Box The function Back to Box resets the CPC12 to the factory settings All configurations are set to default The function is only possible in Admin mode Without a reload the changes will not take effe...

Страница 14: ...e Lock function of the circuit breaker is set to the OFF status the function is only possible in Admin mode and without connection to the fieldbus 4 1 4 2 Reset Devices By selecting this function afte...

Страница 15: ...ith an overview page of all configured parameters First a pop up window asks whether the existing parameters of the current system should be loaded Download Config an already saved configuration file...

Страница 16: ...can be evaluated immediately using the boxes in the area Device This box is di vided into two areas By clicking on these areas it is also possible to navigate the circuit breaker overview page to the...

Страница 17: ...urrent as well as different status messages The upper rectangle contains the currently set cur rent rating Depending on the recent switching state or message the box changes its colour Gray Off Green...

Страница 18: ...n The Restore Factory Settings button resets all pa rameters to the factory settings The Lock selection option blocks switching the cir cuit breaker off or on from the software As soon as the function...

Страница 19: ...breaker are listed Instruction manual Bus Controller CPC12 EN Ref number Y31395702 Index Issue 03 2023 All rights reserved In addition calculated values for the average value in each case are listed N...

Страница 20: ...cx E T A Elektrotechnische Apparate GmbH Industriestra e 2 8 90518 Altdorf Tel 49 9187 10 0 Fax 49 9187 10 397 E Mail info e t a de global e t a com Technical changes misprints and errors reserved Web...

Отзывы: