USE OF ACCESSORIES
All these products can be found on our website at
www.esw-vision.com
The spray
clean
is used to clean and maintain:
• The optical parts of the mobile head of the applicator:
- External optical parts: spray directly and wipe with a dry
cotton cloth.
- Internal optical parts: Never spray directly on the internal
optical parts. Take a dry cotton cloth and spray on the cloth,
and then clean the
filter
(flat red part made of glass) with
this dampened cloth. Finish cleaning with a dry part of the
cloth.
• The device’s touchscreen: Never
spray directly on the touchs-
creen. Take a dry cotton cloth and spray on the cloth, and then
wipe the screen with this dampened cloth.
Finish cleaning with a dry part of the cloth.
These protective shells
eye mask
must be worn by persons
under treatment, and must be adjusted correctly. They protect the
eyes of the patient. Disinfect the shells after each session.
The
gel
must be stored at room tempe-
rature. It is used in a very thick layer (1 cm
in thickness), and is applied progressively
throughout the session, in order to avoid any
drying of
gel
on the skin.. Once used on the
skin and subject to flash exposure, the
gel
must not, under any circumstances, be re-
covered and used on a different zone. Flash
exposure of the
gel
is liable to result in the
modification of its optical characteristics. At
the end of the session, it is removed from the
surface of the skin using a paper towel or a
wet compress. The
gel
is removed from the
optical components and the moving part of
the applicator using a damp cloth, followed
by the application of the
clean
spray.
Ingredients (quantity w/v%): carbomer (0,5-2), TriEtanol Amin
(0,5-2), MonoPropylene Glycol (0,5-2), Dimethicone Copolyol
(0,1-1,0), Isopropyl Myristate (0,1-0,8), Diazolidinyl Urea (0,1-0,8), Glycerin (1,0-5,0), Aloe Vra bar-
badensis (0,2-1,0), Benzyl alcohol (et) Methylchloroisothiazoline (et) Methylisothiazolinone (0,05
– 0,15), Deionized water (Q.S 100).For external use only. Not to be used on broken, burned or infected
skin. Keep out of reach of children.
The tool
extractor
is used for the separation of the mobile head
of your applicator, in order to allow the cleaning of optical compo-
nents or the replacement of the
optic
cartridge.
extractor
geL
clean
eye mask
Made in China
These glasses
mask
may be worn by all persons present during
flashing treatments, for visual comfort during treatment sessions.
After each use, they should be cleaned using the
clean
spray.
mask
Made in China
Made in China
Made in France
Made in Europe
These self-adhesive
patches
are used to mask small areas (such
as beauty spots) which are not to be exposed to flash treatment.
The
patches
must be positioned before the gel is applied. It will
then be possible to administer flash treatment to the entire zone,
regardless of the presence of beauty spots.
patches
are removed
at the end of the session.
patches
Made in France
The
filter
set a fundamental component for the safety of flashes
generated. It may be replaced if required. The cleaning of this com
-
ponent is essential.
filter
Made in France
The spray
clean
must only be used once
the device is unplugged and the optical
parts are cold.
If you intervene after using the
,
you must wait for the fan of the device to
come to a complete stop before unplug-
ging the base. This enables, among other
things, the optical parts to cool down pro-
perly.
optic
Made in France
The
optic
cartridge has a pre-programmed
service life which guarantees the consistent
quality of light emitted, from the first flash
to the very last. The cartridge is supplied
together with its activation card. The
optic
cartridge and its card must be
replaced once the number of
available flashes is expired.
The
stop
plate is constructed of a flash-resistant material. It is
used to mask an area where flash treatment is not to be applied (for
example, tattoos). The glass end of the applicator (optical guide) may
also be positioned to overlap the
stop
plate and the skin.
stop
Made in France