109
Figure 4-87
4.10.3.2 Alarm
Before operation, please make sure you have properly connected alarm devices such
as buzzer.
In the main menu, from Setting->Event->Alarm, you can see alarm setup interface.
For analog channel, the interface is shown as in Figure 4-88 and Figure 4-89 .
For digital channel, there are four alarm types. See Figure 4-88 to Figure 4-91.
Local alarm: The alarm signal system detects from the alarm input port.
Network alarm: It is the alarm signal from the network.
IPC external alarm: It is the on-off alarm signal from the front-end device and can
activate the local HDVR.
IPC offline alarm: Once you select this item, system can generate an alarm when the
front-end IPC disconnects with the local HDVR. The alarm can activate record, PTZ,
snap and etc. The alarm can last until the IPC and the HDVR connection resumes.
Important
If it is your first time to boot up the device, the disconnection status of
the front-end network camera will not be regarded as offline. After one
successfully connection, all the disconnection events will be regarded
as IPC offline event.
When IPC offline alarm occurs, the record and snapshot function of
digital channel is null.
Alarm in: Here is for you to select channel number.
Type: normal open or normal close.
Содержание ECO4 Series
Страница 83: ...80 Figure 4 53 Figure 4 54 4 10 1 3 Encode...
Страница 109: ...106 Figure 4 81 Figure 4 82 Figure 4 83...
Страница 115: ...112 Figure 4 89 Figure 4 90...
Страница 116: ...113 Figure 4 91 Figure 4 92...
Страница 119: ...116 Figure 4 96 Figure 4 97...
Страница 125: ...122 Figure 4 106 Figure 4 107 4 10 4 1 2 2Trigger Snapshot...
Страница 143: ...140 Figure 4 129 For digital channel the interface is shown as below See Figure 4 130 Figure 4 130 4 10 5 5 ATM POS...
Страница 153: ...150 Figure 4 141...
Страница 228: ...225 448K 196M 512K 225M 640K 281M 768K 337M 896K 393M 1024K 450M 1280K 562M 1536K 675M 1792K 787M 2048K 900M...
Страница 244: ...241...