36
Earth cable.
485 A/B
485 communication port. They are used to control devices such as
decoder.
120Ω should be parallel connected between A, B lines if
there are too many PTZ decoders.
T+,T-,R+,R-
They are four-wire full-duplex RS485 port
T+ T-: output wire
R+ R-: input wire
3.7.2 Alarm Input Port
Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
Use the same ground with that of DVR if you use external power to the alarm device.
Figure 3-2
3.7.3 Alarm Output Port
Provide external power to external alarm device.
To avoid overloading, please read the following relay parameters sheet carefully.
RS485 A/B cable is for the A/B cable of the PTZ decoder.
T+,T-,R+,R-
are four-wire double duplex RS485 port.
T+ T-: output wire
R+ R-: input wire
Relay Specification
Model:
JRC-27F
Material of the
touch
Silver
Rating
(
Resistance
Load
)
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Maximum switch voltage
250VAC, 220VDC
Содержание ECO4 Series
Страница 83: ...80 Figure 4 53 Figure 4 54 4 10 1 3 Encode...
Страница 109: ...106 Figure 4 81 Figure 4 82 Figure 4 83...
Страница 115: ...112 Figure 4 89 Figure 4 90...
Страница 116: ...113 Figure 4 91 Figure 4 92...
Страница 119: ...116 Figure 4 96 Figure 4 97...
Страница 125: ...122 Figure 4 106 Figure 4 107 4 10 4 1 2 2Trigger Snapshot...
Страница 143: ...140 Figure 4 129 For digital channel the interface is shown as below See Figure 4 130 Figure 4 130 4 10 5 5 ATM POS...
Страница 153: ...150 Figure 4 141...
Страница 228: ...225 448K 196M 512K 225M 640K 281M 768K 337M 896K 393M 1024K 450M 1280K 562M 1536K 675M 1792K 787M 2048K 900M...
Страница 244: ...241...