17
K000000000EJ 023826A0 100714
6.2 Measurement and Accuracy Ranges
MEASUREMENT
SENSOR
RANGE
RESOLUTION
ACCURACY
O
2
Electrochemical sensor
0 .. 25.0% vol
0.1% vol
±0.2% vol
CO
with H
2
compensation
Electrochemical sensor
0 .. 8000 ppm
1 ppm
±10 ppm 0 .. 200 ppm
±5% measured value 201 .. 2000 ppm
±10% measured value 2001 .. 8000 ppm
diluted
Electrochemical sensor
10.00% vol
0.01% vol
±20% measured value
CO Low range
with H
2
compensation
Electrochemical sensor
0 .. 500 ppm
0.1 ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
diluted
Electrochemical sensor
6250 ppm
10 ppm
±20% measured value
CO Mid range
Electrochemical sensor
0 .. 20000 ppm
1 ppm
±100 ppm 0 .. 2000 ppm
±5% measured value 2001 .. 4000 ppm
±10% measured value 4001 .. 20000 ppm
diluted
Electrochemical sensor
25% vol
0.01% vol
±20% measured value
CO Hi range
Electrochemical sensor
0 .. 10.00% vol
0.01% vol
±0.1% vol 0 .. 2.00 %
±5% measured value 2.01 .. 10.00 %
CO
high immunity H
2
Electrochemical sensor
0 .. 8000 ppm
1 ppm
±20 ppm 0 .. 400 ppm
±5% measured value 401 .. 4000 ppm
±10% measured value 4001 .. 8000 ppm
NO
Electrochemical sensor
0 .. 5000 ppm
1 ppm
±5 ppm 0 .. 100 ppm
±5% measured value 101 .. 5000 ppm
NO Low range
Electrochemical sensor
0 .. 500 ppm
0.1 ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
NOx
Calculated
SO
2
Electrochemical sensor
0 .. 5000 ppm
1 ppm
±5 ppm 0 .. 100 ppm
±5% measured value 101 .. 5000 ppm
SO
2
Low range
Electrochemical sensor
0 .. 500 ppm
0.1 ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
NO
2
Electrochemical sensor
0 .. 1000 ppm
1 ppm
±5 ppm 0 .. 100 ppm
±5% measured value 101 .. 1000 ppm
NO
2
Low range
Electrochemical sensor
0 .. 500 ppm
0.1 ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
CxHy
Pellistor sensor
0 .. 5.00% vol
0.01% vol
±0.25% vol
CO
2
Calculated
0 .. 99.9% vol
0.1% vol
Air temperature
TcK sensor
-20.0 .. 120.0 °C
0.1 °C
±0.5 °C
Flue gas temperature
TcK sensor
-100.0 .. 1250.0 °C
0.1 °C
±0.5 °C 0 .. 100 °C
±0.5% measured value 101 .. 1250 °C
Pressure
(draft & differential)
UNI 10845
Piezoelectric sensor
-1000 .. 20000 Pa
±200 Pa 0.1 Pa
oltre 1 Pa
±0,5 Pa -10.0 .. +10.0 Pa
±2 Pa
-200.0 .. +200.0 Pa
±1% measured value +201 .. +20000 Pa
±1% measured value -1000 .. +201 Pa
Differential temperature
Calculated
0 .. 1250.0 °C
0.1 °C
Air index
Calculated
0.00 .. 9.50
0.01
Excess air
Calculated
0 .. 850 %
1 %
Stack loss
Calculated
0.0 .. 100.0 %
0.1 %
Efficiency
Calculated
0.0 .. 100.0 %
0.1 %
Efficiency
(condensing)
Calculated
0.0 .. 120.0 %
0.1 %
Smoke index
External instrument
0 .. 9
Содержание E4500
Страница 2: ......
Страница 20: ...20 K000000000EJ 023826A0 100714 7 4 Connection diagram AAC SO01 AA SF A AAC TA03A AAC KP01 AA AL05 AA SA08...
Страница 109: ...109 K000000000EJ 023826A0 100714 12 11 Measurements External probe Not available...
Страница 138: ......
Страница 140: ......
Страница 141: ...NOTE...
Страница 142: ...NOTE...
Страница 143: ......