INSTALLATION
2-3
August 2000
Part No. 001-2001-200
2.6.1 AC INPUT REQUIREMENTS
AC Input Voltage:
100-240V AC
Line Frequency:
50-60 Hz
AC In-rush:
60A maximum
Overall Efficiency:
>70% at 100V AC
>80% at 240V AC
Lightning protection:
6kV for < 1ms
Power Factor:
>0.97 at full load
Brown Out Voltage:
80V AC
Temperature
-30°C - +60°C (full power)
Power factor correction per IEC555. The Power
supply has the following safety agency approvals
pending: UL1950, CSA22.2-950, TUV EN60950
(IEC950)
When the AC input voltage is below 90V AC, the
maximum output power is decreased to keep the input
current constant. If a battery back-up is installed, the
batteries take over when the AC input voltage falls
below 80V AC (dependant on power output).
The AC input connector is an IEC connector
equipped with a locking mechanism.
Table 2-1 OUTPUT VOLTAGES
Voltage
Current
Wattage
+26.5V
22A
583W
+15V
5A
75W
+5.2V
5A
26W
-5V
1A
5W
Table 2-2 OVER VOLTAGE
Voltage
Range
+26.5V
+32V to +33V
+15V
+16V to +18V
+5.2V
+6V to +7V
-5V
-6V to -7V
Figure 2-3 POWER CABLE CONNECTOR AND SCHEMATIC
9
7
12
11
10
8
6
5
4
3
2
1
A
B
C
J2
1
2
3
4
5
6
7
8
9
REPEATER
BACKPLANE
AC FAIL IN
POWER SWITCH
THERMAL SENSOR
+15V
N/C
N/C
-5V
TO
POWER HARNESS
GROUND
+15V
+5V
TO
RFIB
+26.5V
A
B
C
1
2
3
4
5
6
7
8
9
10
11
12
3
6
9
8
5
2
1
4
7
J2
BACKPLANE
N/C
Содержание VIKING VX
Страница 2: ...1 2 October 1995 Part No 001 2008 202 ...
Страница 14: ...TABLE OF CONTENTS CONT 10 ...
Страница 24: ...INTRODUCTION AND OPERATION 1 10 August 2000 Part No 001 2001 200 ...
Страница 94: ...CIRCUIT DESCRIPTION 6 44 August 2000 Part No 001 2001 200 ...
Страница 118: ...ALIGNMENT AND TEST PROCEDURES 7 20 August 2000 Part No 001 2001 200 ...
Страница 126: ...SERVICING 8 8 August 2000 Part No 001 2001 200 ...
Страница 160: ...PARTS LIST 9 34 August 2000 Part No 001 2001 200 ...
Страница 197: ......
Страница 198: ...Part Number 001 2001 200 8 00mwp Printed in U S A ...