Side Controls
Push-To-Talk Switch
Pressing the lower half of the rubber switchpad turns the transmitter on. The transmit indicators are the red indica-
tors on the top panel and “TX” in the display.
Auxiliary Switch
Pressing the upper middle part of the rubber switchpad momentarily halts scanning. Pressing it twice within 1
second halts scanning permanently. (To re-enable scanning, press this switch or the SCN key twice.) With a conven-
tional system selected, this switch enables the monitor mode.
Turning power on with this switch pressed enables a menu for selecting keypad enable/disable, key press tone
enable/disable, high/low power, and loud/soft clear-to-talk tone.
Backlight Switch
Pressing the upper part of the rubber switchpad turns on the backlight. The backlight automatically turns off 8
seconds after this switch is released or it can be turned off by pressing this switch again.
Front Panel Controls
S (System)
Pressing this key increases the selected system. Holding the key down causes the function to repeat. Only
programmed systems can be selected. To decrease the system number, press the 2ND key and then this key.
G (Group)
Functions like the S (System) key to change the selected group.
NOTE: If equipped with the optional telephone keypad, the next three keys have a different function in the phone
mode. Refer to “Optional Keys For Telephone Calls” for more information.
RTN (Return)
Pressing this key once enables the second function of the S, G, SCN, and LCK keys. The display momentarily indi-
cates “2ND” when the second function is enabled. Pressing this key again displays the home or last active system/group
(see “Return Key” description).
SCN (Scan)
Pressing this key turns the System Scan feature on and off. Scanning is enabled when “SCN” is indicated in the
lower part of the display. When scanning is actually occurring, “IN SCAN” is indicated in the upper part of the display
and the group number is replaced by a dash ( - ). See page 31 for more information.
Pressing the 2ND (RTN) key and then this key programs the current quick select switch position with the displayed
system/group (unless the position is locked). Refer to “Quick Select Switch” description for more information.