CONVENTIONAL FEATURES
37
Keypad programming allows conventional
channel parameters such as the transmit and receive
frequency, Call Guard squelch code, and encryption
key to be changed. In addition, several conventional
mode timers can be changed. It cannot be used to
reprogram disabled channels or any P25 Trunked,
SMARTNET, or SmartZone information.
5.17.2 MENU STRUCTURE
A menu system is used to select parameters in the
keypad programming mode. Rotate and press the
Select switch to scroll through and select the available
parameters. The available parameters and the section
in which each is described are as follows:
•
CHNG ZONE (5.17.4)
•
CHNG CHAN (5.17.5)
•
SYS PARMS (5.17.6)
•
CHAN PARMS (5.17.7)
Press the Select switch to select the displayed
parameter. Press the
PROG
option switch from one of
the main menus to exit keypad programming or from
other menus to exit back one level. A flowchart
showing the keypad programming mode menu struc-
ture is located Figure 5-1. Refer to the descriptions
which follow for more information.
Figure 5-1 5300 Keypad Programming Menu
Flowchart
5.17.3 ZONE PASSWORD
NOTE:
Make sure that the zone password(s) are not
lost because they cannot be overridden in the field.
The PCConfigure software must be used to display the
lost password or program a new password.
Each zone can be programmed with a password
by the PCConfigure software to prevent unauthorized
reprogramming of zone by keypad programming.
When this password is programmed, it must be entered
before system or channel parameters in that zone can
be changed by keypad programming. The zone pass-
word is programmed in the Zones > Edit Zone screen
of the PCConfigure programmer. This screen is
displayed by clicking the Edit Zone button. A different
password can be programmed for each zone.
When an attempt is made to select a system or
channel parameter in a password protected zone,
“PASSWORD” is flashed. The password is always
eight digits long and is entered using the same proce-
dure as used for the power-up password described in
Section 3.2. After the password is entered, system and
channel parameters for that zone can be reprogrammed
normally.
5.17.4 ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for
normal operation.
Press the Select switch to select the “CHNG
ZONE” parameter and then scroll through the
programmed zones by rotating that switch. When the
desired zone is displayed, select it by pressing the
Select switch.
5.17.5 CHANNEL CHANGE PARAMETER
The “CHNG CHAN” menu parameter selects the
conventional channel to be reprogrammed. Disabled or
P25 Trunked/SMARTNET/SmartZone channels
cannot be selected. This does not change the channel
selected for normal operation.
Press the Select switch to display “CHNG
CHAN” and then scroll through the programmed
Change
Change
Channel
Zone
System
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx (Time-Out) Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Timer On-Off
Sq Adjust*
Chan Space*
Tlk Grp ID Sel**
* Analog only ** Digital only
Tx Type Sel***
*** Mixed Mode Ch Only
Chan Alias
Strapping
Key Select