background image

CONVENTIONAL MODE FEATURES

20

May 2002

Part No. 002-5100-100

or the F2 key. If talk group selection has been 
disabled on the channel by programming, “NO 
LIST” is displayed, a tone sounds, and no change 
occurs.

Unit Calls

Unit Calls (also called Individual Calls) can be 

placed to a specific radio on a Project 25 channel if the 
Unit Call option key or menu parameter is 
programmed. This call differs from standard group 
calls in that only one mobile instead of entire groups 
of mobiles may receive the call. The mobiles that can 
be called are preprogrammed by you system operator. 
Proceed as follows to transmit and receive a Unit Call:

1. To transmit a unit call, press the Unit Call option key 

or select the Unit Call menu parameter. The alias 
(tag) of the last Unit Call is displayed.

2. If required, press the Up/Down switch to display the 

desired call. The alias and ID of the unit calls that 
have been programmed are alternately displayed.

3. Press the PTT switch and begin talking.

4. When a unit ID call is received, two beeps sound (if 

tones are enabled), and “Call Rcvd” and the alias or 
frequency of the currently selected talk group are 
alternately flashed. 

The transceiver may also be programmed to display 
the alias of the channel on which the call is being 
received (if it is not the same as the selected 
channel) and/or the ID of the mobile placing the 
call.

5. To respond, select the Unit Call mode by pressing 

the Unit Call option key or selecting the menu 
parameter. The following operation then occurs:

If a unit call has been programmed with the ID of 
the calling mobile, it is automatically selected. A 
response can then be made without changing the 
selected channel.

If no Unit Call has been programmed with the ID 
of the calling mobile, a response may have to be 
made in the standard mode.

If the call timer times out (set by programming) or 
the channel is changed before a response is made, 
the unit call mode is exited. 

Keypad Programming

NOTE: The Keypad programming feature is available 
to Federal Government users only. Users regulated by 
the Federal Communications Commission are not 
allowed to have this feature. 

Introduction

Keypad programming is available on Federal 

radios if the Keypad Programming option key or menu 
parameter is programmed. It is then selected by simply 
pressing that key or selecting that menu parameter. 
The keypad programming mode is indicated by 
“ZONE CHG” and 

 in the display.

Keypad programming allows conventional 

channel parameters such as the transmit and receive 
frequency and Call Guard squelch code to be changed. 
In addition, several conventional mode timers can be 
changed. It cannot be used to reprogram disabled 
channels or any SMARTNET/SmartZone information.

Menu Structure

A menu system is used to select parameters to be 

changed in the keypad programming mode. A flow-
chart showing the keypad programming mode menu 
structure is located in Figure 6. 

When the keypad programming mode is selected 

by the Keypad Programming option key or menu 
parameter, the first menu parameter “CHNG ZONE” 
is displayed as just described. Press the Up/Down 
switch to scroll through the available parameters 
which are listed below. 

CHNG ZONE

CHNG CHAN

SYS PARMS

CHAN PARMS

Press the F2 (Select) key to select a highlighted 

parameter, and press the F1 key from one of the main 
menus to exit keypad programming. Pressing it in the 
other menus returns to the previous menu. Information 

Содержание 5100 Series

Страница 1: ... OPERATING MANUAL 5100 SERIES PORTABLE RADIO VHF UHF 800 MHZ PROJECT 25 CONVENTIONAL SMARTNET SMARTZONE 7 2 VDC 1 and 5 Watts VHF 1 and 4 Watts UHF 1 and 3 Watts 800 MHz Part No 242 51xx xxx First Issue May 2002 Supersedes Part No ...

Страница 2: ...red continuously Pressing the PTT switch on the side usually causes the radio to transmit DO NOT use any accessories not specifically autho rized by the E F Johnson Company for use with this radio such as batteries speaker microphones belt clips and antennas The use of unauthorized accesso ries can cause FCC RF exposure compliance require ments to be exceeded ALWAYS keep the antenna and radio at l...

Страница 3: ...Guard PCConfigure and PCTune are trademarks of the E F Johnson Company SMARTNET SmartZone SecureNet Call Alert Enhanced Private Conversation and Private Conversation II are trademarks of Motorola Inc All other company and or product names used in this manual are trademarks and or reg istered trademarks of their respective manufacturer The IMBE voice coding technology embodied in this product is pr...

Страница 4: ... 16 Monitor Mode 16 Busy Channel Lockout 16 Call Guard Squelch 17 Call Guard Squelch Enable Disable 17 Selective Squelch Code Select 17 Penalty Timer 17 Conversation Timer 18 Repeater Talk Around 18 Displaying Transmit and Receive Frequency 18 Emergency Mode 18 Conventional Mode Scanning 18 Priority Channel Sampling 18 Changing the Priority Channel 19 Placing and Receiving Conventional Calls 19 Pr...

Страница 5: ...smit disable on busy DES OFB encryption available P25 channels Unit Individual ID calls on Project 25 channels Keypad programming Fed Gov users only Emergency key Project 25 channels SMARTNET SmartZone Features Group Enhanced Private Conversation Private Conversation II and Telephone Calls Emergency alarms to alert a dispatcher of emergency conditions Emergency calls for high priority system acces...

Страница 6: ...own Switch Selects zones when multiple zones are programmed Pressing the upper part of the switch selects the next higher number and pressing the lower part selects the next lower number This control also provides up down select in the menu mode and in other modes when up down select is required F1 In menu mode functions as a step back and exit key If menu mode is not used it is a programmable opt...

Страница 7: ...tion point for the antenna Make sure the antenna is tight before using the radio Emergency Key This key or some other option key can be programmed as an Emergency key to alert a dispatcher of an emergency condition Refer to pages 18 and 28 for more information This key can also be programmed for other functions Side Controls Figure 3 Side Controls and Jacks PTT Push To Talk Switch This switch is p...

Страница 8: ...Power is turned on and off by the top panel On Off Volume switch When power is initially turned on the transceiver goes through a self test routine in which the following information is displayed Currently selected zone Individual ID of the radio if a conventional P25 channel is selected Unit ID of the radio if a SMARTNET SmartZone channel is selected Selected channel alias last Programming determ...

Страница 9: ... a tone sounds if tones are enabled When conventional channels are selected and the Display Information option key or menu parameter is programmed either the channel frequency or alias can be displayed see page 18 Low Battery Indication NOTE If the transceiver contains hardware encryp tion keys be sure to reattach a battery within approxi mately one minute to prevent the loss of these keys A low b...

Страница 10: ... roaming SmartZone only telephone private and emergency calls Call Alert and messaging Either analog or digital signaling may be used Operating features unique to SMARTNET SmartZone operation are described starting on page 23 When a SMARTNET or SmartZone channel is selected or the radio is powered up on one of those channels it searches for a control channel Once a control channel is found it atte...

Страница 11: ...and return to normal operation RADIO WIDE FEATURES Option Keys Almost all the transceiver keys are programmable unless they are dedicated to a specific function These keys can be programmed by your system operator for one set of functions in the Conventional mode and another in the SMARTNET SmartZone mode as described on page 10 Table 5 on page 12 lists the programmable keys the functions that can...

Страница 12: ...to page 17 for more information Table 5 Programmable Option Key and Menu Mode Functions Function Menu Display Available in Mode See Description on Page Conv SMARTNET SmartZone Alert tones On Off Tones X X X 13 Backlight On Off Backlight X X X 9 Call Alert Select X X 27 Call Response Select X X 24 Clear Secure Select Security X X X 10 Digital Talk Group Select Select TG X 19 Display Information Sel...

Страница 13: ...e standard type is unique to the type of channel selected and the operation of Radio Wide type is the same regardless of the type of channel selected Only one type can be enabled at a time For example if standard scanning is enabled and radio wide scanning is selected standard scanning is automatically disabled More information on these types of scanning follows Standard Scanning Standard scanning...

Страница 14: ... again The selected channel is changed Scan Lists Radio Wide Scan List With radio wide scanning there is only one scan list available regardless of the type of channel selected and it is not user programmable This scan list can contain up to 16 channels of any type For example it could include six conventional channels and ten SMARTNET SmartZone channels Standard Mode Scan Lists NOTE The selected ...

Страница 15: ...ional and SMARTNET SmartZone standard scan lists can be programmed as follows Changes are permanent cycling power does not reselect a default condition 1 Make sure that both standard and radio wide scan ning are off icon not displayed Select a conventional or SMARTNET SmartZone channel corresponding to the scan list being programmed 2 Select the scan edit mode using the Scan Edit option key or men...

Страница 16: ...green the channel may be busy and a call should not be placed see next para graph Monitor Mode There may be times when a busy condition is indicated even though no one is using the channel Monitoring should then be performed by enabling the monitor mode described next The Normal Selective function may also be used on analog channels see description on page 17 Monitor Mode The monitor mode temporar...

Страница 17: ...ist have been programmed This feature allows the normal transmit and receive Call Guard programming to be temporarily overridden with a code selected from this list This code list is programmed with up to sixteen CTCSS and DCS codes for use on analog channels plus up to sixteen NAC codes for use on digital Project 25 channels When a selective squelch Call Guard code is changed as describe below it...

Страница 18: ...If the Displayed Information option key or menu parameter is programmed it can be used to display the channel frequency in megahertz Pressing this key toggles between displaying the standard channel alias and the channel frequency The receive frequency is displayed when receiving and the transmit frequency is displayed when transmitting This feature is available on conventional channels only Emerg...

Страница 19: ...g responses may occur on the priority selected or receive channel as described in the preceding information Project 25 Digital Mode Features Viewing Individual ID Each transceiver which operates on Project 25 digital channels is assigned an eight digit individual ID When power is turned on with a Project 25 channel selected the individual ID of your radio is briefly displayed Group IDs Each Projec...

Страница 20: ...d A response can then be made without changing the selected channel If no Unit Call has been programmed with the ID of the calling mobile a response may have to be made in the standard mode If the call timer times out set by programming or the channel is changed before a response is made the unit call mode is exited Keypad Programming NOTE The Keypad programming feature is available to Federal Gov...

Страница 21: ...el selected for normal operation Press the F2 key to select the CHNG CHAN parameter and then scroll through the programmed channels by pressing the Up Down switch When the desired channel is displayed select it by pressing F2 key System Parameters NOTE If ENTER PSWD is briefly displayed when attempting to select a parameter see Zone Password description on page 21 The SYS PARMS menu parameter sele...

Страница 22: ...e as RX CODE above NAC Squelch Control Project 25 Channel RX NAC Programs the Network Access Code NAC which can be any number from 0 4095 The procedure is similar to programming a RX FREQ just described If an invalid code is entered a beep sounds INVALID is briefly displayed and the code must be re entered TX NAC Selects the transmit NAC the same as RX NAC above TX POWER Selects the desired power ...

Страница 23: ... is not programmed with the proper encryption key KEYFAIL is displayed and the call must be made in the clear mode or the proper key must be programmed If the busy tone sounds and BUSY is displayed the system is busy Release the PTT switch and wait for the call back tone to sound Then press the PTT switch within 3 seconds If a continuous tone sounds and NO SYS is displayed you may be out of range ...

Страница 24: ... to the bulleted list which follows Item 3 in the next section for events that may occur next Direct Entry Using DTMF Keypad 1 Press and hold the Private Call option key until a tone sounds approximately 1 second The last ID called is displayed and the private call mode is indi cated by in the display 2 Using the 0 9 keys dial the ID of the mobile you are calling all six digits To erase the last d...

Страница 25: ...isplay indicates the alias of the ID if it matches an ID in the call list Otherwise the ID you entered continues to be displayed Events that may then occur are as follows The called party answers the call The called party does not answer Press the Private Call option key or F1 Exit to end the call If the selected mobile ID is not valid INVALID is displayed and an alert tone sounds If the radio sys...

Страница 26: ...until a tone sounds approximately 1 second The alias of the last called telephone number is displayed if it is in the phone number list Otherwise the last eight digits of the last called telephone number are displayed The interconnect call mode is indicated by in the display 2 Enter the telephone number using the 0 9 and keys To enter a pause indicated by P press and then To erase the last digit p...

Страница 27: ...ivate Call option key or select that menu parameter and the alias of the mobile paging you is displayed Press the PTT switch and respond One of the conditions that follow may also occur Enhanced Private Conversation Mode If the mobile being called is on the air ringing is heard until the called party answers or for 20 seconds whichever occurs first If no answer occurs within 20 seconds NO ANS is d...

Страница 28: ...pressing the PTT switch One of the following events then occurs If five beeps sound the status was received and acknowledged by the dispatcher If after 6 seconds the message is not acknowl edged a tone sounds and NO ACK is displayed Press and release the PTT switch to send it again or press the Status option key or F1 Exit key to exit this mode and return to normal operation Emergency Alarm and Ca...

Страница 29: ...in the current system can be temporarily changed The procedure is described on page 15 The default scan list for all groups is reselected on power up SMARTNET SmartZone lists are also user programmable if the Scan Edit option key is programmed In addition nuisance channels can be temporarily deleted see page 13 Scanning is enabled and disabled by the Scan option key or menu parameter Also channels...

Страница 30: ...arch mode press the Site Search option key again or the F1 Exit key To scroll through the other programmed sites press the Up Down switch while SITE xx or RSSI xx is displayed To select the displayed site press the Site Search option key or the F2 Select key If site lock is on when site search is entered see following the radio will be locked on the new site when this function is exited Locking Un...

Страница 31: ... was sent has not been acknowledged page 28 Five Beeps Recurring The page was received page 27 Two Short Tones A private call was received page 24 Five Beeps The paged mobile received the page and acknowl edged it page 27 The message that was sent has been received and acknowledged page 28 The status condition that was sent has been received and acknowledged page 28 Four Beeps The emergency alarm ...

Страница 32: ...de 12 Messaging 29 Microphone 7 Monitor Mode 17 Monitoring Before Transmitting 17 N NAC 20 O On Off Volume Control 8 Operating Modes 11 Option Key 8 Alert Tone 14 Backlight 10 Call Alert 28 Call Response 26 Clear Secure 11 24 Displayed Information 19 Emergency 19 29 High Low Power 14 Home 14 Key Select 12 Keypad Lock 11 Keypad Programming 21 Message 29 Monitor Mode Select 17 Normal Selective 18 Ph...

Страница 33: ...tandard Calls Conventional 20 Standard Calls SMARTNET SmartZone 24 Status Messages SMARTNET 29 Supervisory Tones 31 T Telephone Calls SMARTNET 27 Time Out Timer 13 Tone Select 14 Tones 31 Transmit Disable On Busy 17 Transmitting Scan Mode 15 19 U Unit Calls P25 21 Unit ID SMARTNET 24 Unit To Unit Calls SMARTNET 25 Up Down Button 7 V Voice Encryption 11 Volume Setting 9 W Warranty 3 Z Zone Select 1...

Страница 34: ...Part Number 002 5100 100CD 5 02hph Printed in U S A ...

Отзывы: