User Manual HTS801
Humidity and Temperature Sensor for High Humidity and Chemically Polluted Conditions | 32
4.7.2.
Pressure-tight Installation
Mounting of sensing probe with screw connection (accessory)
A.1/2".ISO.or.a.1/2".NPT.screw.connection,.respectively,.is.available.as.an.accessory.for.mounting.both.sensing.
probes.(6.mm.(1/4").and.12.mm.(1/2")).
Order codes:
RH probe (12 mm (1/2"))
T probe (6 mm (1/4"))
1/2”.ISO
HA011102
HA011104
1/2”.NPT
HA011103
HA011105
For mounting instructions please refer to chapter 4.4.2. Pressure-tight Installation.
4.8
Remote Sensing Probes Type T28
The sensing probes type T28 are optimised for application in
meteorology. Their rotation symmetric design allows for mounting
in a modern ventilated radiation shields, as it is available with
HA010508 (please refer to chapter
).
5 Electrical Connection
NOTICE
The electrical installation of the HTS801 shall be performed by qualified personnel only. Observe all
applicable national and international requirements for the installation of electrical devices as well as for
power supply according to EN 61140, class III (EU) and class 2 supply (North America).
WARNING
Incorrect installation, wiring or power supply may cause overheating and therefore personal injuries or
damage to property.
For correct cabling of the device, always observe the presented wiring diagram for the product version used.
The manufacturer cannot be held responsible for personal injuries or damage to property as a result of
incorrect handling, installation, wiring, power supply and maintenance of the device.