27
7.
TECHNICAL DATA - EE300Ex-HT
Measuring values
Relative humidity
Humidity sensor
1)
HC1000
Measuring range
1)
0...100% RH
Accuracy
2)
(including hysteresis, non-linearity and repeatability, traceable to international standards, administrated by NIST, PTB, BEV...)
-15...40°C
(5...104°F)
≤
90% RH
± (1.3 + 0.3%*mv) % RH
-15...40°C
(5...104°F)
>90% RH
± 2.3% RH
-25...70°C
(-13...158°F)
± (1.4 + 1%*mv) % RH
-40...180°C
(-40...356°F)
± (1.5 + 1.5%*mv) % RH
Temperature dependence electronics
typ. 0.03% RH/°C
Response time with filter at 20°C
(68°F)
/ t
90
< 30 sec.
Temperature
Temperature sensor
Pt1000 (Tolerance class A, DIN EN 60751)
Measuring range sensor head
wall mounting:
-40...60°C
(-40...140°F)
remote sensing probe: -40...180°C
(-40...356°F)
Accuracy
Temperature dependence of electronics
typical 0.005 °C/°C
Max. selectable Scaling Range
from
to
unit
wall mounting
remote sensing probe
Dew/Frost point temp.
Td
-40 (-40)
60 (140)
100 (212)
°C
(°F)
Wet bulb temperature
Tw
0
(32)
60 (140)
100 (212)
°C
(°F)
Water vapour pressure
e
0
(0)
200 (3)
1100 (15)
mbar (psi)
Mixing ratio
r
0
(0)
425 (2900)
999 (9999)
g/kg (gr/lb)
Absolute humidity
dv
0
(0)
150 (60)
700 (300)
g/m
3
(gr/ft
3
)
Specific enthalpy
H
-50 (-15000)
400 (150000)
2800 (999999)
kJ/kg (Btu/lb)
Water activity
aw
0
-
1
[ ]
Water content
x
0
-
100000
[ppm]
Outputs
freely selectable and scalable outputs
2 x 4 - 20 mA (2-wire) galvanically isolated
R
L
=(Vcc-9V)/20mA
Output 1 (CH1) must be connected!
General
Supply voltage (Class III)
V
cc min
=(9+R
L
*0.02)VDC V
cc max
=28VDC
Current consumption
max 20mA per channel
Pressure range for pressure tight sensor probe
refer to model
Serial interface for communication
3)
RS232
System requirements for software
WINDOWS XP or later
Protection class of housing
IP65; NEMA 4
Cable gland
M16 for cable diameter 5 - 10 mm
(0.2 - 0.4“)
Electrical connection
screw terminals max. 1.5 mm²
(AWG 16)
Temperature range
sensor head
according measuring range
electronic
-40...60°C
(-40...140°F)
electronic with display
-20...60°C
(-4...140°F)
Storage temperature range
electronic and sensor head
-20...60°C
(22...140°F)
Electromagnetic compatibility according
EN61326-1
EN61326-2-3
ICES-003 ClassB
Industrial Environment
FCC Part15 ClassB
Material
Housing
Stainless Steel 1.4404
Probe cable
PTFE
Probe (without Filter)
Stainless Steel
1) Refer to the working range of the humidity sensor.
2) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation).
The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).