User Manual EE074 Temperature Probe with Modbus RTU

1  General

This user manual serves for ensuring proper handling and optimal functioning of the device. The user 

manual shall be read before commissioning the equipment and it shall be provided to all staff involved 

in transport, installation, operation, maintenance and repair. The user manual may not be used for the 

purposes of competition without the written consent of E+E Elektronik® and may not be forwarded to 

third parties. Copies may be made for internal purposes. All information, technical data and diagrams 

included in these instructions are based on the information available at the time of writing.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.1.1  General Safety Instructions

•  Avoid any unnecessary mechanical stress and inappropriate use.

•  Installation, electrical connection, maintenance and commissioning shall be performed by qualified 

personnel only.

•  Use the EE074 only as intended and observe all technical specifications.

•  Do not use EE074 in explosive atmosphere or for measurement of aggressive gases.

•  Do not apply the nominal voltage to the RS485 data lines.

1.1.2  Mounting, Start-up and Operation

The EE074 Modbus RTU temperature probe has been produced under state of the art manufacturing 

conditions, has been thoroughly tested and has left the factory fulfilling all safety criteria. The manufac-

turer has taken all precautions to ensure safe operation of the device. The user must ensure that the 

device is set up and installed in a manner that does not have a negative effect on its safe use. The user 

is responsible for observing all applicable safety guidelines, local and international, with respect to safe 

installation and operation on the device. This user manual contains information and warnings that must 

be observed by the user in order to ensure safe operation.

•  Mounting, start-up, operation and maintenance of the device may be performed by qualified staff only. 

Such staff must be authorized by the plant operator to carry out the mentioned activities.

•  The qualified staff must have read and understood this user manual and must follow the  

instructions contained within.

•  All process and electrical connections shall be thoroughly checked by authorized staff before putting 

the device into operation.

•  Do not install or start-up a device supposed to be faulty. Make sure that such devices are not 

accidentally used by marking them clearly as faulty.

•  A faulty device may only be investigated and possibly repaired by qualified, trained and authorized 

staff. If the fault cannot be fixed, the device shall be removed from the process.

•  Service operations other than described in this user manual may only be performed by the 

manufacturer. 

Disclamer

In any case, the scope of liability is limited to the corresponding amount of the order issued to the  

manufacturer. The manufacturer assumes no liability for damages incurred due to failure to comply with 

the applicable regulations, operating instructions or the operating conditions. Consequential damages 

are excluded from the liability

Содержание EE074

Страница 1: ...BA_EE074_e V1 0 technical data are subject to change User Manual EE074 Temperature Probe with Modbus RTU...

Страница 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Страница 3: ...5 4 2 Duct Mount 6 4 3 Immersion Well Mount 6 4 4 Recommendations for Accurate Temperature Measurement 6 5 Modbus Map 7 5 1 Modbus Setup 7 5 2 Modbus Register Map 7 5 3 Modbus RTU Example 8 6 Maintena...

Страница 4: ...facturing conditions has been thoroughly tested and has left the factory fulfilling all safety criteria The manufac turer has taken all precautions to ensure safe operation of the device The user must...

Страница 5: ...in mm inch 82 3 23 L 12 0 47 6 0 24 L in mm L in Inch 70 2 81 155 6 16 305 12 07 3 2 Connectivity 4 Installation 4 1 Wall and Ceiling Mount Best measurement performance is achieved when the entire pr...

Страница 6: ...4 Recommendations for Accurate Temperature Measurement Air Temperature Measurement In air best accuracy is achieved with an air flow of min 0 2 m s surrounding the sample In case the EE074 probe is no...

Страница 7: ...dbus protocol settings see Application Note Modbus AN0103 available on www epluse com EE074 INFO read register Parameter Register number1 DEC Protocol address2 HEX Read only register function code 0x0...

Страница 8: ...any special maintenance nevertheless for high accurate measurements especially over wide T ranges it is recommended to calibrate the probe every 12 months If needed the enclosure may be cleaned and t...

Страница 9: ...ed setup or adjustment mode from the main EE PCS menu on the left and follow the online instructions of the EE PCS PC HA011018 6 4 T Adjustment and Calibration 6 4 1 Temperature Adjustment and Calibra...

Страница 10: ...ectronics 40 80 C 40 176 F 0 100 RH probe 70 155 mm 40 80 C 40 176 F 0 100 RH probe 305 mm 70 105 C 94 221 F 0 100 RH Storage conditions 40 80 C 40 176 F 0 90 RH Immersion well Material brass nickel p...

Страница 11: ...0 6460 Office Stuttgart Tel 49 151 538 37 500 E E Elektronik Italy info epluse it Tel 39 02 2707 86 36 E E Elektronik France info epluse fr Tel 33 4 74 72 35 82 E E Elektronik USA office epluse com Of...

Отзывы: