3
escaping into the installation room.
• After boiler start up, you should request information about operating the boiler and safety
precautions from qualified person.
Usage and Maintenance
• Read carefully instructions and precautions in this manual against wrong usage which causes
unsafe conditions.
• The boiler should be checked and serviced for general maintenance once a year. Maintenance
and service operations must be carried out only qualified person.
• Only a damp cloth should be used for cleaning the outer surface of the boiler and then the
surfaces should be dried completely. Do not use chemical substances or solutions which cause
rust and scratches in your appliances.
PRODUCT
General Specifications
SCOT high efficiency condensing boilers have been designed for providing efficient, safe and
comfortable central heating (CH) and domestic hot water (DHW). The boilers are suitable for only
room sealed operation and are supplied for use with both natural gas and LPG.
Main board provides all the functionality and safety of the boiler. The board drives gas valve, fan,
pump and 3-way-valve. Flame in burner is checked regularly.
The control panel has been designed ergonomically. Scot condensing boiler having visualized plastic
control panel and advanced LCD display provides ease for user and service. Operation modes, actual
and setpoint CH, actual and setpoint DHW, parameter menu, Error Codes can be seen on LCD display.
There are two DHW option;
Comfort Mode (Adaptive pre-heating control) / Normal Mode
◊ Comfort mode keeps the domestic water in a preheated condition depending on the user’s habit.
The DHW habit of the user is recorded. These recorded data is taken into account to control preheat
function the next day at the same time. (24 hours later)
◊ Normal mode is for the economical DHW control, ie. Without DHW preheat.
The safety systems in your appliance provide entire safety for you and your appliance. The safety
systems are;
• Flue Gas Over-heat Safety System (105 °C)
• Flame Failure Safety System
• Boiler Over-heat Safety System (2 levels: 95 °C and 105 °C)
• DHW (Domestic Hot Water) Over-heat Safety System
• High Water Pressure Protection System (3 bar)
• Low Voltage Protection System (160 VAC)
• High Voltage Protection System (260 VAC)
• EMC (Electromagnetic Compatibility) Filter
CAUTION: The device can cause vital dangerous situation and material
damage incase of misuse or inapropriate usage.