32
8) Pump and 3 Way Valve Blockage Protection Function:
Blockage protection protects the pump against blockage in cases when the pump is not in use for a
long period. This function enables the pump to be operated for a few seconds in CH position when
the pump is not operated within the recent 24 hours.
The same feature is also valid for 3 way valve. 3 way valve protection protects against blockage by
enabling the changing of the direction of 3 way valve if it has not changed its direction in the recent
24 hours.
User’s Parameter Menu
• It is pressed on the “i” button on the control panel in order to enter the user’s parameter menu.
• By the help of the “COMFORT” and “ECO” buttons, you can see the required values by transiting
among codes whose descriptions are available in Table 3
Figure 29
Table 3
Code
Description
Range
Unit
A0
System’s water pressure
0
4
bar
A1
CH water flow temperature
-9
110
°C
A2
CH water return temperature
-9
110
°C
A3
Flue gas temperature
-9
110
°C
A4
Flow rate of domestic hot water
0
19,9
lt/min
A5
Temperature of external air sensor
-9
100 ya da "- -"
°C
A6
Instant combi modulation value
0
100
%
A7
Pwm pump signal
0
100
%
A8
Temperature of domestic hot water (for
ones with boiler)
-9
110
°C