9
-PART DEFINITIONS & MAINTENANCE INSTRUCTIONS
CONDENSATE TRAP
Subject
Description
Part Function
It is the component allowing the discharge of condensate and rain
water without allowing the exhaust gas discharge
Impact in case of Faulty
Operation
1- Raise of water in condensate trap due to clogging of condensate
trap
2- Discharge of exhaust gas from condensate trap’s drain to outdoor
Primary Relevant Error
Codes
-
Troubleshooting and
Testing Method
Visual inspection and cleaning of any dirt, burrs, etc. inside
condensate trap cleaning steps:
1- Move the condensate trap up and down.
2- Rotate it counterclockwise.
3- Pull it downward by hand or a hand tool.
4- Rinse any dirt in the condensate trap.
5- If any, remove any deposits in the condensate hose.
Maintenance Period
Once a year or if condansete trap is blocked, according to instruction
written above.