LIST OF SERVICE PARAMETERS
E2prom parameters
PR
PR
PR
PR
PR
PR
Category
Unit
PREMIX PREMIX PREMIX PREMIX PREMIX PREMIX
Parameter
Description
14
20
24
28
30
35
1=Instant
aneous
2=Instant
Solar
Boiler
P00
DHW
3=Storag
Num.
1
1
1
1
1
1
Type
configuration e tank
4 = Solar
storage
tank
5 = CH
only
Gas type selection 0 =
Natural gas
�
1 = LPG
Gas Type
P01
Num.
0
0
0
0
0
0
CH
P26
CH burner of duration
Min.
3
3
3
3
3
3
CH
P27
CH pump additional
operation time
Min.
1
1
1
1
1
1
CH
P33
OTC curve selection
Num.
0
0
0
0
0
0
System
1 – Emas Hydroblok
(CCB Pakkens)
Configuration
DHW
P37
(Water
2 - Fugas Hydroblock Num.
1
1
1
1
1
1
pressure
c flow
sensor circuit) 3 - Bitron Hydroblock
Heating
0- Radiator heating
CH
P38
system type
Num.
0
0
0
0
0
0
1- Floor heating
CH
P39
Eco mode burner on set value
Num.
1
1
1
1
1
1
DHW Hysteresis OFF
DHW
P42
0: OFF at 71°C
Num.
0
0
0
0
0
0
1: Standard algorithm
System
P43
ASE maintenance counter reset
Res
System
P44
Room thermostat activation
Num.
Table
5
. Service Parameters
1
1
1
1
1
1
The service personel may access to and amend only “P00, P01, P26, P27, P33, P37, P38, P39, P42
, P43, P44
”
parameters out of the following parameters.
20