8
Hanging the Appliance to the Wall
E.C.A. Phoenix gas water heater must be hung to a brick wall with the supplied hanging bracket.
Figure 5-
Hanging bracket
For installation:
Take measurement from the back side of the boiler to make sure that the holes are in line and horizontal.
Mark the hole places on the wall.
Drill the holes and put in the wall plugs.
Fix the hanging bracket to the wall using the provided screws.
Hang the boiler to the hanging bracket.
It is important that the hanging parts should be fixed to the wall properly to endure the weight of the
appliance.
CONNECTIONS
Flue Connections
E.C.A. Phonex gas water heates are designed to work with C-type flues to provide the air required for burning
from out of boiler room. During flue connections tightness gaskets should be mounted correctly to prevent flue
gas leakage to the fresh air intake.
Hanging bracket
ALLOWABLE POSITION
DISTANCE
(cm)
ALLOWABLE POSITION
DISTANCE
(cm)
A - Below a window
60
G
-
Beside an horizontal or a vertical
pipe
60
B - Below an air vent
60
H
- An outer corner of the building
30
C - Below a rain channel
30
I
- An inner corner of the building
100
D - Below balcony
30
L
- From the floor
180
E - Beside a window
40
M
-
Vertical distance between two
chimney outlets
150
F - Beside an air vent
60
N
-
Horizontal distance between two
chimney outlets
100
Figure 6-
Distances for Flue Outlets