TROUBLESHOOTING 

ERROR CODE 

POSSIBLE CAUSE 

SOLUTION 

ON/OFF boiler is not started. 

Electrical supply is not provided. 

Check the plug. 
If it is OK, call an authorized service. 

AL0

1

Flame loss fault

Call an authorized service 

AL0

7

DHW Solar sensor fault

Cable connection fault. 

Call an authorized service 

AL11  

Gas valve parasite fault 

Electr

o

nic board is damaged. 

Call an authorized service 

AL37  

Low voltage supply fault 

Voltage supply is out of the limits 

Call an authorized service 

AL41 

Loss of flame for more than 6

 

consecutive 

times fault 

Wrong installation of gas water heater 

Call an authorized service 

AL62 

Calibration request fault 

Call an authorized service 

AL72 

NTC Measurement fault

NTC is not placed well 

Call an authorized service 

AL81 

Bad combustion at start-up 

Bad combustion at start-up 

Check the chimney inlet and outlet. If the error 
continues,

 

call an authorized service. 

AL82 

Bad combustion fault 

Bad combustion. 

Check the chimney inlet and outlet. If the error 
continues,  call an authorized service. 

AL83 

Temporary bad combustion warning 

Recirculation due to extraordinary 
windy weather conditions. 

Fault disappears automatically. 

FX

Long-term fault.

 

If the temperature measured by DHW NTC 
sensor is lower than 3°C
this fault occurs.

Call an authorized service 

Product specifications are subject to change without notice.

  ALL RIGHTS RESERVED 

AL02 

Overheating 

fault 

Overheating cable is cut off 

Call an authorized service 

Cable connection fault. 

AL06 

NTC fault 

Cable connection fault.

Call an authorized service 

AL

40

Frequency measurement fault

Call an authorized service 

AL

42

Button fault

Call an authorized service 

AL

43

OT Communicaiton Anomally

Call an authorized service 

AL

44

Anomaly triggered for gas valve no 
flame time-out

Call an authorized service 

AL7

0

DHW Solar sensor overheating fault

Call an authorized service 

AL

80

SGV Drive fault

Call an authorized service 

AL8

4

Temporary combustion fault

Call an authorized service 

AL

12

Gas valve cable

 fault 

Gas valve cable is damaged. 

Call an authorized service 

AL

28

Non-resettable lock-out

The 6 allowed lock-outs have been 

exceeded

Call an authorized service 

Cable connection fault.

Gas valve 

fault.

Cable connection fault. 

NTC is not placed well 

Cable connection fault. 

Bad combustion. 

AL86

 

Fan hall effect sensor fault 

Call an authorized service 

Fan hall effect sensor cable is 

disconnected. 

 

AL

98

 

Software 

fault 

Call an authorized service 

AL

99

Generic anomaly

 

fault

Call an authorized service 

FE

Frost protection

Call an authorized service 

Содержание PHOENIX PH HM 11

Страница 1: ...PHOENIX PH HM 11LT MIN WATER HEATER User And Installation Manual ...

Страница 2: ...am 5 Components 6 PACKAGING 6 INSTALLATION AND CONNECTIONS 7 Selecting the Suitable Place for Installation 7 CONNECTIONS 8 Flue Connections 8 Horizontal Flue Connections 9 Vertical Flue Connections 11 Chimney Lenght Setting Definitions 12 Gas and Water Connections 12 Electrical Connections 13 START UP 13 Final Checks And Operations Before Start up 13 CONTROL PANEL 14 ON OFF Temperature Setting Kno...

Страница 3: ...hnical service For the warranty to be valid warranty documents must be filled and stamped by the service during start up This E C A product does not require repairment under normal working conditions But if you need any assistance you can call service company For the warranty to be valid all maintenance and repairs must be done by an authorized technical service personnel Authorized technical serv...

Страница 4: ...t piping system is out of warranty coverage Installation of Gas Water Heater Installation of this gas water heater must be done by a authorized technical service according to the information placement flue connections etc presented by the standartds and authorized gas companies After the installation installer must make sure that user has given the user manual and give all the necessary informatio...

Страница 5: ...rd provides all the functionality and safety of the water heater Burner is made of stainless steel withstands thermal stress Burner performs silently and provides efficient and clean combustion as a result of the homogeneous dispersion of gas Heat exchanger is made of copper and designed for thermal shock absorbing It has long life high productivity and is non calcerous as well Functions and the s...

Страница 6: ... Flowrate 0 9 m3 h Gas Inlet Pressure Natural Gas 20 mbar Domestic Hot Water Minimum Water Flowrate 2 5 lt min Maksimum Water Flowrate 11 Δt 25 lt min Minimum Operation Pressure 0 2 bar bar Max Operation Pressure 10 bar bar Temperature Setting Range 35 60 C General Electrical Supply 230V 50Hz VAC Hz Electrical Consumption 35 W NOx Class 6 Dimensions HxWxD 654x352x268 mm Weight net 16 kg Table Gas ...

Страница 7: ...pe 6 Flow Sensor 12 Water Inlet Pipe PACKAGING CAUTION Warnings on the packaging must be followed during transportation and storage The appliance is delivered in a 760x440x330 mm carton box with 2 pieces of styrofoams supporting the appliance Parts required for the installation of the product Wall hanging bracket 3 gaskets for water and gas connection 3 wall plugs for screws is provided in the pac...

Страница 8: ...sh air to the installation room Danger The water heater location and air flue terminal position must obey national and local requirements gas safety regulations and relevant standarts The water heater is not suitable for external installation It should be within in the building In case of gas leakage it is necessary to vent the installation room according to national and local requirements althoug...

Страница 9: ...ECTIONS Flue Connections E C A Phonex gas water heates are designed to work with C type flues to provide the air required for burning from out of boiler room During flue connections tightness gaskets should be mounted correctly to prevent flue gas leakage to the fresh air intake Hanging bracket ALLOWABLE POSITION DISTANCE cm ALLOWABLE POSITION DISTANCE cm A Below a window 60 G Beside an horizontal...

Страница 10: ... or condensation from entering the heater If the air flue kit length is insufficient additional flue accessories should be ordered through qualified service Do not use any other type brand name of flue parts Horizontal air flue kit accessories fig 7 a Concentric extension L 500 mm φ60 100 mm 7006902786 Concentric extension L 1000 mm φ60 100 mm 7006902787 b 90 Concentric elbow φ60 100 mm 7006902785...

Страница 11: ...Connections 1 Vertical Flue Kit Ø60 100mm 7006902326 2 Vertical Flue Adapter Ø60 100mm 7006901413 3 Extension Pipe 500mm 1000mm Ø60 100mm 7006901415 7006901416 4 45 Elbow Ø60 100mm 7006901420 5 90 Elbow Ø60 100mm 7006901421 Figure 10 Vertical Flue Types ...

Страница 12: ...p of gas water heater changing chimney lenghts of installation and changing the electronic board Product Elbow L m Lmax m P11 Parameter Setting value PHOENIX PH HM 11 1x90 1 4 4 1x90 1 2 1x90 2 3 1x90 3 4 2x90 1 3 3 2x90 1 2 2x90 2 3 3x90 1 2 2 3x90 1 2 Table 3 Serviceman must save the flue lenght info When switch on the power at first time FA symbol is seemed on the screen with fan icon Servicema...

Страница 13: ...sion 14mm for cables or 16mm for conduits Supply cable of the appliance must be connected to a grounded plug that can supply the required voltage 230V AC 50 Hz Mainboard failures due to voltage fluctations and unfit grounding is not covered by warranty START UP Final Checks And Operations Before Start up Open hot water tap to check the water circuit Check any leakage water pipes Check whether flue...

Страница 14: ...horized technical person e Entering parameters menu and parameter adjustment for authorized technical person LCD Display Water heater functions water temperature set and actual values fault error conditions can be seen on LCD Fig14 Figure 14 LCD Screen Fan symbol Shown in case choosing the flue lenght value Failure symbol Shown in case error conditions Single Button Rotate Push Black LCD Screen Te...

Страница 15: ...le dashe is shown on the screen after closing the gas water heater by pushing the button 1 minute later double dash disappears Frost Protection Ante Freeze Function The appliance goes on and off automatically depending on actual water temperature values measured by the water temperature sensor for protecting water circuit against freezing If the water sensor measures a low water temperature in the...

Страница 16: ... term fault If the temperature measured by DHW NTC sensor is lower than 3 C this fault occurs Call an authorized service Product specifications are subject to change without notice ALL RIGHTS RESERVED AL02 Overheating fault Overheating cable is cut off Call an authorized service Cable connection fault AL06 NTC fault Cable connection fault Call an authorized service AL40 Frequency measurement fault...

Страница 17: ...e Label Calculations 1 PRODUCT FICHES Product fıche for combination boilers as required by EU regulations No 812 2013 Supplier s name or trademark Supplier s model identifıer Water heating load profile Efficiency Class Water heating Annual electric consumotion Water heating Rated heat output Prated Temperature Setting Range Sound Power Level Lwa indoors Specifıc precautions for assembly installati...

Страница 18: ......

Страница 19: ...18 ...

Страница 20: ... A S Esentepe Mah Kasap Sok No 15 1 34394 Sisli ISTANBUL Tel 90 212 370 14 00 Fax 90 212 370 14 01 email satis emas com tr www emas com tr SERVICE EMAR A S SERVIS MÜDÜRLÜGÜ Esentepe Mah Kasap Sok No 15 1 34394 Sisli ISTANBUL Tel 90 216 458 45 00 pbx Fax 90 216 305 65 43 email emar emarservis com tr www emarservis com tr E C A Call Center 444 0 322 EMAS A S EMAR A S ARE SUBSIDIARIES OF ELGINKAN GRO...

Отзывы: