User Self Help Fault Guide

This guide is intended for user's self help only. For technical  in depth fault finding please see 
installation & service instructions.

Your Confeo Premix boiler has a built in self checking function and fault diagnosis display. These 
fault codes will help to interpret the nature of fault. Some faults conditions will be reset by pressing 
the 

Reset Push-button / Burner LED         (fig 1) 

which will be

 RED 

if a fault condition occurs or 

by an automatic reset if fault is corrected.

Fault finding actions should only be under taken where user is competent to undertake. 

Table 1

Fault

Display

Remedy

LED display not lit up 

Check on / off control knob is on.
Check external fused switch is on.
Are all house electrics on
Replace 3 amp fuse in fused switch.

No DHW when tap 
opened (LED display on)

Ensure good flow from tap or try 
different tap.
Make sure DHW knob is not set to 
DHW cancellation mode

No Central Heating 
(LED display on)

Turn CH control knob to maximum.
Check external time clock and room 
thermostat are calling for heat.
(set to maximum)

No Central Heating
DHW indication on

Check if taps are running / leaking 

No CH or DHW
Display shows 40

Low System Pressure
Press pressure button, pressure must 
be at least 0.6 bar. If below follow 
re-filling instructions

No CH or DHW – LED 
light red, display shows 4

Press Red LED to re-set, if fault 
code reappears.
Check Gas supply is on and in credit
Check Condensate drain is not 
blocked

This is only a brief summary of the fault codes that may be displayed. In the event of other 
fault codes being displayed, please contact your installer to investigate if a system or product 
fault exists.

ECA Warranty Service Helpline 0845 4637 803

Local Call rate charges apply
Web self help 

www.ecaheating.com/selfhelp

Registered Office - ECA Heating UK Ltd – 1 Bray Place, London SW3 3LL

6

Содержание Confeo Premix

Страница 1: ...Confeo Premix CP 24 HM GC Appliance No 47 144 03 24 kW Central Heating Output 26 kW Domestic Hot Water Output Confeo Premix CP 30 HM GC Appliance No 47 144 04 30 kW Central Heating Output 31 kW Domestic Hot Water Output USER OPERATING INSTRUCTIONS Veruk23308 ...

Страница 2: ...affect your statutory rights under UK or IE consumer law The Benchmark Scheme ECA Heating is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hot water...

Страница 3: ...Display Panel Blue Backlit LCD Display and 4 Yellow Status LED s Central Heating CH Temperature Control Knob Domestic Hot Water DHW Temperature Control Knob Pressure Push button Reset Push button Burner LED Control Panel Cover 2 4 5 7 3 1 Fig 1 6 ...

Страница 4: ...g 4 and also domestic hot water Fig 5 Adjust the CH water flow temperature between 30 o C and 80 o C with the CH control knob The setpoint value appears on the LCD display when the left dot is flashing After 10 seconds actual CH water temperature will appear instead of the setpoint and left dot disappears The boiler will modulate to the desired temperature If a hot water tap is opened DHW mode wil...

Страница 5: ...eat function Economy Mode Comfort Mode maintains the DHW plate heat exchanger in a preheated condition dependent upon usage patterns to ensure fast delivery of hot water Preheat cycle typically last less than 1 minute In economy Mode DHW preheat function is cancelled To select Comfort Mode turn the DHW temperature control knob fully clockwise and then back to the desired DHW temperature setting wi...

Страница 6: ...ontrol panel and monitor pressure increase 6 Fill when cold to approximately 1 bar cold range 0 6 1 5 bar once reached turn off filling loop taps If water goes over pressure reduce by draining a small amount from heating system drain offs 7 Remove filling loop copper pipe A refit plug ends and reset DHW CH control knobs to required temperatures Frost Protection The bolier will go on and off automa...

Страница 7: ...od flow from tap or try different tap Make sure DHW knob is not set to DHW cancellation mode No Central Heating LED display on Turn CH control knob to maximum Check external time clock and room thermostat are calling for heat set to maximum No Central Heating DHW indication on Check if taps are running leaking No CH or DHW Display shows 40 Low System Pressure Press pressure button pressure must be...

Отзывы: