HW (Domestic Hot Water) Mode 

It is possible to have domestic hot water when: 
 a) The appliance is in standby-by mode or,                                                      

Fig 8

 b) CH mode is active. DHW has priority over CH 
mode.                                                                            

Ensure control knob is not in DHW cancellation zone. 
Turn ON a hot tap to start DHW mode  
Turn OFF the hot tap to stop DHW mode. The boiler 
goes back to the previous mode.

                                                                                                                     

        Fig 9

Domestic hot water temperature can be adjusted between 
35 

o

C and 60 

o

C with the DHW control knob. The setpoint 

DHW temperature appears on the LCD display and left dot 
is flashing. (fig 9)

After 10 seconds, actual CH water temperature will appear 
instead of the setpoint and left dot disappears. Boiler will 
modulate to the desired temperature (fig. 10).
                                                                                                                            

Fig 10

Comfort Mode (DHW Preheat function) / Economy Mode

Comfort Mode maintains the DHW plate heat exchanger in a preheated condition dependent upon 
usage patterns to ensure fast delivery of hot water. Preheat cycle typically last less than 1 minute. In 
economy Mode DHW preheat function is cancelled.  

To select Comfort Mode, turn the DHW temperature 
control knob fully clockwise and then back to the desired 
DHW temperature setting within 3 seconds. Status LED 
Comfort mode will 

ON

 

                     

                                                             Fig 11

To select economy mode, i.e. without DHW preheat, do the same action again (turn the DHW 
temperature control knob fully clockwise and then back to the desired DHW temperature setting 
within 3 seconds). Status LED Comfort mode will 

OFF

DHW Cancellation Function

DHW mode has priority over CH mode, but DHW can be turned off. Turn DHW control knob 
(fig. 8) fully anti clockwise. In DHW cancellation zone, it is not possible to have domestic hot water 
even if a hot water tap is open. 

Содержание Confeo Premix

Страница 1: ...Confeo Premix CP 24 HM GC Appliance No 47 144 03 24 kW Central Heating Output 26 kW Domestic Hot Water Output Confeo Premix CP 30 HM GC Appliance No 47 144 04 30 kW Central Heating Output 31 kW Domestic Hot Water Output USER OPERATING INSTRUCTIONS Veruk23308 ...

Страница 2: ...affect your statutory rights under UK or IE consumer law The Benchmark Scheme ECA Heating is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hot water...

Страница 3: ...Display Panel Blue Backlit LCD Display and 4 Yellow Status LED s Central Heating CH Temperature Control Knob Domestic Hot Water DHW Temperature Control Knob Pressure Push button Reset Push button Burner LED Control Panel Cover 2 4 5 7 3 1 Fig 1 6 ...

Страница 4: ...g 4 and also domestic hot water Fig 5 Adjust the CH water flow temperature between 30 o C and 80 o C with the CH control knob The setpoint value appears on the LCD display when the left dot is flashing After 10 seconds actual CH water temperature will appear instead of the setpoint and left dot disappears The boiler will modulate to the desired temperature If a hot water tap is opened DHW mode wil...

Страница 5: ...eat function Economy Mode Comfort Mode maintains the DHW plate heat exchanger in a preheated condition dependent upon usage patterns to ensure fast delivery of hot water Preheat cycle typically last less than 1 minute In economy Mode DHW preheat function is cancelled To select Comfort Mode turn the DHW temperature control knob fully clockwise and then back to the desired DHW temperature setting wi...

Страница 6: ...ontrol panel and monitor pressure increase 6 Fill when cold to approximately 1 bar cold range 0 6 1 5 bar once reached turn off filling loop taps If water goes over pressure reduce by draining a small amount from heating system drain offs 7 Remove filling loop copper pipe A refit plug ends and reset DHW CH control knobs to required temperatures Frost Protection The bolier will go on and off automa...

Страница 7: ...od flow from tap or try different tap Make sure DHW knob is not set to DHW cancellation mode No Central Heating LED display on Turn CH control knob to maximum Check external time clock and room thermostat are calling for heat set to maximum No Central Heating DHW indication on Check if taps are running leaking No CH or DHW Display shows 40 Low System Pressure Press pressure button pressure must be...

Отзывы: