Fig. 4 indicates minumum clearances from the ceiling and the sides.
a)
b)
fig. 4
- The appliance should be mounted against a closed wall.
- The outer surface of the water heater do not exceed 85
o
C in maximum running mode so do not
take additional precautions againts constructional materials (combustible materials)
WARNING: Do not block the air vents which provide fresh air to the installation room.
WARNING: The water heater location and air/flue terminal position must obey
national and local requirements, gas safety regulations and relevant standarts.
¨
The water heater is not suitable for external installation. It should be within in the building.
- In case of gas leakage, it is necessary to vent the installation room according to national and local
requirements, although the water heaters are independent of room volume and ventilation.