20
Fault/Error and error code
Cause
Solution
No flame signal
(ON)
+
FL
(blink)
+
“key” icon (ON)
- No flame in burner after 3 ignition
trials (burner start is unsuccessful).
- Reset procedure is necessary.
- If the lockout condition continues after
reset, consult qualified service.
Flame simulation
FS
(blink)
+
“key” icon (ON)
- A flame detected before gasvalve ON. - Reset procedure is necessary.
- If the lockout condition continues after
reset, consult qualified service.
Flame simulation
FE
(blink)
+
“key” icon (ON)
- A flame detected after gasvalve OFF.
- Reset procedure is necessary.
- If the lockout condition continues after
reset, consult qualified service.
Frozen
Ic
(blink)
+
“key” icon (ON)
- The water temperature measured by
the probe is too low.
-
The anomaly disappears if the water
temperature increases.
MAINTENANCE
- The water heater should be checked and serviced for general maintenance once a year.
Maintenance and service operations must be carried out only by qualified person.
- Only a damp cloth should be used for cleaning the outer space of the heater and then the surfaces
should be dried completely. Do not use chemical subtances or solutions which cause rust in your
appliance.
STANDARDS AND REGULATIONS
During the installation and operation of the water heater, the instructions and precautions detailed in
this manual and also all relevant standards and local regulations must be obeyed.
ALL
RIGHTS
RESERVED
Product specifications are subject to change without notice.
FACTORY
EMAS MAK
İ
NA SANAY
İ
A.
Ş
.
Organize Sanayi Bölgesi
Mustafa Kemal Bulvarı
No:13 Manisa
Tel : (+90 216) 378 34 00
Fax: (+90 216) 378 20 59
E-mail:
www.emas.com.tr
SALES:
EMAS MAK
İ
NA SANAY
İ
A.
Ş
.
Yal
ı
Mah. Ziya Gökalp Cad. No: 3
34844
Maltepe/
İ
stanbul TURKEY
Tel : (+90 216) 458 92 00
Fax: (+90 216) 441 50 49
Fax: (+90 216) 458 92 93
E-mail:
www.eleks.com.tr