13.1.3
Tariff control register
13.1.4
Tariff control with terminals
The tariff registration is controlled with the terminals 13 and 15 according to the following table. The
tariff control mode can be set in the configuration register.
Terminal
Activated tariff
13
15
0 V
0 V
T1
230V
AC
0 V
T2
0 V
0 V
T2
230V
AC
0 V
T1
Table 8 Tariff control modes
-
In case of two energy direA/-A the tariff registers x.8.1 and x.8.2 are controlled
simultaneously
-
Terminal control has lower priority than LMN-interface (commands)
13.1.5
Tariff control LMN-interface
-
The first command activates tariff function for LMN. The tariff control for terminals is
deactivated.
-