![Dynon Avionics FlightDEK-D180 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/dynon-avionics/flightdek-d180/flightdek-d180_installation-manual_2550925026.webp)
Transducer Installation
3-8
FlightDEK-D180 Installation Guide
are converting from a GRT EIS system, you must disconnect the external resistor pull-up from
the fuel pressure output. This will make the sensor output equivalent to the sensor supplied by
lace the
ase
y sandwiching a ground-
Dynon Avionics.
Injected engines:
Use the 0-80 PSI sensor (Dynon P/N 100411-001). Crimp a standard #8 ring
terminal onto the brown wire from pin 8. Unscrew the stud cap from the threaded stud. P
ring terminal on the stud and secure the cap down sandwiching the ring terminal. If the
connection between the sensor and your engine is non-metallic, you must connect the sensor c
to ground through other means. The best way to accomplish this is b
connected ring terminal between the sensor and the mating fitting.
Due to vibration issues, never connect the sensor directly to engine.
If you use Teflon tape or other seal, ensure the sensor casing still maintains a good
connection to ground.