DYNISCO UPR800 Series Instruction Manual
Page | 74
Lower display:
LI.TYP
Range:
OFF, AL, P, AL-P. Disabled, alarm reset, peak reset, alarm and peak
reset
Default value:
Alarm and peak reset
LOGIC INPUT STATUS - Group 4
Available:
Only if LI.TYP is different than OFF.
Upper display:
Status of logic input.
Lower display:
LI.STS
Range:
CLOSE, OPEn. The logic input is considered active when the contact
is closed or open with respect to this parameter.
Default value:
Closed.
PEAK DETECTION - Group 4
Available:
Always.
Upper display:
Polarity of peak detector
Lower display:
PEAK
Range:
OFF, HI, LO. Disabled, maximum peak, minimum peak
Default value:
Maximum peak
PRESSURE INPUT DISPLAY UPDATE TIME - Group 4
Available: Always.
Upper display:
Display update time for the pressure input.
Lower display:
PI.DUT
Range: 0.050,
0.100,
0.250,
0.400
sec.
Default value:
0.400 sec.
SECONDARY INPUT SAMPLE TIME - Group 4
Available:
Only if SI.FNC is equal to ‘tenp’.
Upper display:
Sample time for the secondary input.
Lower display:
SI.ST
Range: 0.100,
0.200,
0.500,
1.000
sec.
Default value:
0.500 sec.
LINE FREQUENCY - Group 4
Available: Always.
Upper display:
Line frequency rejection.
Lower display:
LINE.F
Range: 50,
60,
Auto
50 Hz, 60 Hz, automatic detection of the line frequency (except
24Vdc power supply).
Default value:
Auto.
LINE FREQUENCY READOUT - Group 4
Available:
Only when the LINE.F parameter is set to Auto.
Upper display:
Read-only value of the detected line frequency.
Lower display:
LINE.R