DYNISCO UPR800 Series Instruction Manual
Page | 67
Upper display:
Time constant of the second analog output filter.
Lower display:
SO.FL
Range:
OFF, 0.4, 1, 2, 3, 4, 5 sec.
Default value:
0.4 sec.
LOADING DEFAULT DATA - Group 2
Available:
Only if access to level B is allowed.
Upper display:
OFF
Lower display:
DEFLT
Range:
Use
u t
keys to switch the upper display from OFF to On 2, then
press FUNC key to load the default data of the parameters belonging
to Group 1 and Group 2.
12.3 Group 3 Parameters
PRIMARY INPUT FULL SCALE VALUE - Group 3
Available:
Always
Upper display:
Full scale value
Lower display:
PI.FSV
Range:
From 10 to 99950. Changes to this value causes loading of the
default values for the pressure input low scale, the alarm set points,
the retransmission limits and the secondary input low/high range, if
the latter is configured for differential pressure measurement
Default value:
10000.
PRIMARY INPUT LOW SCALE VALUE - Group 3
Available:
Always
Upper display:
Low scale value
Lower display:
PI.LSV
Range:
from -/+25% of Full scale value
Default value:
0
PRIMARY INPUT DECIMAL POINT POSITION - Group 3
Available:
Always
Upper display:
Full scale value
Lower display:
PI.DP
Range:
Use
u t
keys to select the position of the decimal point
Default value:
None
PRESSURE INPUT ENGINEERING UNIT - Group 3
Available: Always.
Upper display:
Engineering unit beacon to lit up.
Lower display:
PI.EU
Range:
OFF, PSI, bAr, hGcn2, nPa, where: OFF is all beacons are turned
off; PSI is first beacon (PSI) lit; bAr is second beacon (Bar) lit; hGcn2
is third beacon (kg/cm
2
) lit; nPa fourth beacon (MPa) lit
Default value:
PSI.