Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
71
HYDRAULIC ROTARY VANE COMPRESSORS
TECHNICAL SPECIFICATIONS
10. TECHNICAL SPECIFICATIONS
HKL 400
/8-24
HKL 801
/8-26
HKL
1300
/8-38
HKL
1300
/8-46 *
HKL
1800
/8-46
DISCHARGE CHARACTERISTICS
Flow rate max. at ref.
conditions **
l/min
(cfm)
400
(14)
800
(28)
1300
(46)
1300
(46)
1800
(64)
Pressure max.
bar (psi)
8
(116)
Compressed air connection
AP
BSP 3/8”
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 3/4”
HYDRAULIC CONNECTIONS
Pressure line
P
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 1/2”
Return line
T
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 1/2”
BSP 1/2”
Drain line
D
-
-
-
-
-
HYDRAULIC POWER REQUIREMENTS
Oil flow min.
l/min
(gmp)
10
(2.64)
14
(3.70)
20
(5.28)
23
(6.08)
23
(6.08)
Oil flow max.
l/min
(gmp)
35
(9.25)
37
(9.77)
60
(15.85)
66
(17.44)
66
(17.44)
Pressure at nominal flow
bar (psi)
120
(1740)
210
(3046)
210
(3046)
170
(2466)
210
(3046)
Pressure max.
bar (psi)
250
(3626)
Pressure when unloaded
bar
(psi)
80
(1160)
140
(2031)
150
(2176)
130
(1885)
150
(2176)
HYDRAULIC FLUID REQUIREMENTS
Viscocity
cSt
10-200 / optimum 25-35
Temperature ***
° C (° F)
max. 70
(158)
Filter ratio
μm
25 or better
OVERALL DIMENSIONS
Length
mm (in)
525
(20.7)
640
(25.2)
640
(25.2)
640
(25.2)
810
(31.9)
Width
mm (in)
250
(9.8)
320
(12.6)
320
(12.6)
320
(12.6)
390
(15.4)
Height
mm (in)
325
(12.8)
520
(20.5)
520
(20.5)
520
(20.5)
620
(24.4)
Weight
kg (lbs)
30
(66.1)
55
(121.3)
55
(121.3)
55
(121.3)
103
(227.1)
Gallons are U.S. liquid gallons
* Low pressure model (170 bar).
** According to ISO 1217
(19.6)
at discharge pressure of 6 bar.
Содержание HKL 1300
Страница 2: ......