DYNAPAR NorthStar SLIM Tach SL56 Скачать руководство пользователя страница 4

NorthStar SLIM Tach

®

 SL56 Instruction Manual

CHAPTER 1

INTRODUCTION

1.0  Safety Summary

High current, voltage, and rotating parts can cause serious or fatal injury. The use of electric machinery, like all other uses of 
concentrated power and rotating equipment, may be hazardous. Installing, operating, and maintaining electric machinery 
should be performed by qualified personnel, in accordance with applicable provisions of the National Electrical Code and 
sound local practices. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates 
safety standards of design, manufacture, and intended use of the instrument. Dynapar assumes no liability for the customer's 
failure to comply with these requirements.

Rotating Machinery

Avoid contact with rotating parts. Avoid by-passing or rendering inoperative any safety guards or protection devices. Avoid 
extended exposure in close proximity to machinery with high noise levels. Use proper care and procedures in handling, lifting, 
installing, operating and maintaining the equipment.

Before Installation

Safe maintenance practices with qualified personnel is imperative. Before starting maintenance procedures, be positive that, (1) 
equipment connected to the shaft will not cause mechanical rotation, (2) main machine windings have been disconnected and 
secured from all electrical power sources, and (3) all accessory devices associates with the work area have been de-energized. 
If high potential insulation test is required, follow procedures and precautions outlined in NEMA standards MG-1.

Grounding

Improperly grounding the frame of the machine can cause serious or fatal injury to personnel. Grounding of the machine frame 
and structure should comply with the National Electrical Code and with sound local practices. Check wiring diagram before 
connecting power.

Do Not Operate In An Explosive Atmosphere

Do not operate the instrument in the presence of flammable gases or fumes. Operating any electrical instrument in such an 
environment constitutes a definite safety hazard.

Keep Away From Live Circuits

Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by 
qualified maintenance personnel. Do not replace components with power cable connected. To avoid injuries, always 
disconnect power and discharge circuits before touching them.

Do Not Substitute Parts Or Modify Instrument

Do not install substitute parts or perform any unauthorized modification to the instrument. Introducing additional hazards is 
dangerous. Return the instrument to an authorized Dynapar representative for service and repair to ensure that safety features 
are maintained.

Dangerous Procedure Cautions

A CAUTION heading precedes potentially dangerous procedures throughout this manual. Instructions in the warnings 

must

 be 

followed.

4                                                                    

©

 

DYNAPAR                                                              +1.800.873.8731 

Содержание NorthStar SLIM Tach SL56

Страница 1: ...APAR 1 800 873 8731 791 1007 00 Rev H Website www dynapar com brand Customer Service Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com Technical Support Tel 1 800 234 8731 Fax 1 847 782 5277...

Страница 2: ...2 DYNAPAR 1 800 873 8731...

Страница 3: ...ector 11 2 5 Returning NorthStar brand Equipment to Dynapar 11 Methods and apparatus disclosed and described herein have been developed solely on company funds of Dynapar No government or other contra...

Страница 4: ...from all electrical power sources and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required follow procedures and precautions outli...

Страница 5: ...s the passing magnetic pulses actuate the magnetoresistive sensor The resulting electronic signals are processed into square wave signals by the internal electronics 5 DYNAPAR 1 800 873 8731 ULatching...

Страница 6: ...airs Input Voltage 5 0 to 15 0 VDC Mechanical Specifications Maximum Operational Speed 5 000 RPM Nominal Air Gap 0 019 0 008 inch Shaft Axial End Play Up to 0 045 inch maximum Enclosure Configuration...

Страница 7: ...ce company Please advise us of such filing In case of parts shortages advise us immediately Dynapar cannot be responsible for any missing parts unless notified within 60 days of shipment 2 1 Motor Fac...

Страница 8: ...shaft until the edge of the pulse wheel is flush with the machined recess in the encoder frame See Figure 4 We recommend you use a straight edge for this purpose For best results align the two surfac...

Страница 9: ...me Insert and tighten four Phillips head screws This completes the mechanical mounting of the unit UNOTE Be sure the letter Z and This Side Out are visible on the face of the pulse wheel after install...

Страница 10: ...o Connection Vcc 5 15 VDC B A Z Shield 1 2 3 4 5 6 7 8 9 10 Black Green Blue Violet Red Yellow Gray Orange Braid F B A C E D I H J G Applies only to units with index pulse capability Pinouts are for t...

Страница 11: ...body and Sensor Module can be improved by smearing a sealant silicone grease etc on the neoprene seal of the connector 5 Mate connector into place on sensor mount and snap the two latches into place...

Страница 12: ...31 Fax 1 847 662 4150 custserv dynapar com Technical Support Tel 1 800 234 8731 Fax 1 847 782 5277 northstar techsupport dynapar com Website www dynapar com European Sales Representative Hengstler Gmb...

Отзывы: