2.4 Quick Release Connector Hood Wiring
To install the Quick Release Connector, perform the following steps.
1. Remove the four screws from the mating connector housing that hold the terminal block in place. Remove terminal block
from housing.
2. Insert wiring through liquid tight flexible seal and mating connector housing. Leave enough wire exposed to comfortably
reach the terminal block. Wire to terminal block according to wire code in Table 1. A similar wiring list is attached to
enclosure.
NOTE
There are two orientations of the connector hood. The terminal block can be inserted
either way so the connector hood points up or down. Choose the direction best for your
application.
4. Tighten Liquid Tight fitting on housing.
OPTIONAL
: In some hostile environments, seal between connector body and
Sensor Module can be improved by smearing a sealant (silicone grease, etc.) on the neoprene seal of the connector.
5. Mate connector into place on sensor mount and snap the two latches into place. If only one sensor is being installed,
ensure cover plate is installed over other sensor hole.
Figure 5: Sealed Industrial Latching Connector
2.5 Returning Equipment to Dynapar
If it is necessary to return the unit for repair or replacement, a Return Goods Authorization (RGA) number must be obtained
from a factory representative before returning the equipment to our service department. When returning an instrument for
service, the following information must be provided before we can attempt any repair.
1. Instrument model and serial number
2. User’s name, company, address, and phone number
3. Malfunction symptoms
4. Description of system
5. Returned Goods Authorization number
Consult the factory for shipping instructions.
11
©
DYNAPAR +1.800.873.8731
Terminal Block
1/2 inch NPT
Mating Connector Housing
Liquid Tight Fitting
Conduit