27
ILH800EN2
MAINTENANCE – AFTER THREE YEARS / 1000 HOURS OF OPERATION
Changing eccentric element oil
L000587A
1
4
2
3
1. Eccentric element
2. Oil basin
3. O-ring
4. Screws
1. Dismount the eccentric element (1) and clean the oil
basin (2) at the bottom plate.
2. Refill with 0,5 l oil, Shell Universal Engine Oil TX 15-
40.
3. Before mounting the eccentric element, grease
surfaces between eccentric element and ground
plate.
4. Use new O-ring, P/N: 904923 (3) and torque the
screws (4) crosswise dry to 320 Nm.