13
CC 100 M100EN1
EVERY 50 HOURS OF OPERATION (Weekly)
Air cleaner
Checking the indicator
Make sure that the engine hood is fully open. Change
or clean the main filter (4) fig.13 of the air cleaner when
the indicator (1) is in the red zone while the engine is
running at full revs.
Fig. 14 Main filter
Fig. 12 Air cleaner
1. Indicator
1
Air cleaner
Dismantling - Assembly
1. Loosen the wing nut (5) and pull out the main filter
(4). Do not remove the backup filter (2).
2. Wipe the outside of the filter housing clean with a
clean rag. Change or clean the main filter.
Fit a new backup filter every third time the
main filter is changed, or after cleaning it three
times. The backup filter cannot be cleaned
and reused.
1
2
3
4
5
Fig. 13 Air cleaner
1. Filter housing
2. Backup filter
3. Wing nut
4. Main filter
5. Wing nut
3. Blow up and down the inside of the filter element.
Hold the nozzle at least 20 or 30 mm (0.8 or 1.2 in)
away from the pleats to avoid tearing the paper.
Change the main filter after cleaning it five
times.
Wear protective goggles when working
with compressed air.
Main filter - Cleaning with
compressed air