Maintenance measures - 250 h
4812165301.pdf
2022-09-02
Battery
- Check condition
Figure. Batteries
The batteries are sealed and maintenance-free.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
The cable shoes should be clean and tightened.
Corroded cable shoes should be cleaned and greased
with acid-proof Vaseline.
Wipe the top of the battery.
Air conditioning (Optional)
- Inspection
Fig. Air conditioning
1. Refrigerant hoses
2. Condensor element
1
2
Inspect refrigerant hoses and connections and make
sure that there are no signs of an oil film that can
indicate a refrigerant leakage.
The refrigerant contains tracing liquid, which makes it
possible to detect leaks with the aid of a UV lamp. If
the areas around the connections are strongly
coloured, this is an indication of a leak.
129
Содержание CA3500DCP
Страница 2: ......
Страница 22: ...Safety Optional 4812165301 pdf 2022 09 02 10...
Страница 26: ...Special instructions 4812165301 pdf 2022 09 02 14...
Страница 36: ...Technical specifications 4812165301 pdf 2022 09 02 24...
Страница 45: ...Machine description 4812165301 pdf 2022 09 02 4812129673 Warning CALIFORNIA Proposition 65 33...
Страница 112: ...Operating instructions Summary 4812165301 pdf 2022 09 02 100...
Страница 114: ...Preventive maintenance 4812165301 pdf 2022 09 02 102...
Страница 124: ...Maintenance Maintenance schedule 4812165301 pdf 2022 09 02 112...
Страница 178: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...