13
IP:
the current IP address of your managed member--DYNAMIX DH - 114 M (the IP of RMU). It's a fixed IP if
the DHCP Client is disabled or the IP obtained from DHCP Server when DHCP Client is enabled.
Net Mask:
the subnet mask of IP LAN environment
Default Gateway:
the Router/Gateway IP address for the WAN/LAN connectivity of the managed member
User Name:
username to login the member
Password:
password to login the member
Confirm Password:
retype and confirm the login password.
Telnet/FTP/SNMP/SNMP Trap Port Number:
the assigned port for the utility to access the managed
member. The default port number Telnet:
8861
, FTP:21, SNMP:161, SNMP Trap:162. The utility uses ‘Telnet’
for remote configuration and ‘FTP’ for remote firmware upgrading. The SNMP monitoring utility queries the
managed agent through ‘SNMP’ port and intercepts any trap on ‘SNMP Trap’ port.
DHCP Client:
Enable the RMU to obtain the ‘
IP
’, ‘
Net Mask
’ and ‘
Default Gateway
’ fields from DHCP Server.
The previous Property/SNMP window let you activate ‘SNMP trap’ operation, you can setup at most five hosts
for receiving trap. Field ‘IP’ sets to ‘
0.0.0.0
’ will be disabled. Please refer the section entitled ‘SNMP’ in Chapter 5
for more SNMP details.
Click button ‘
CHANGE
’ to accept the configuration and store the setting into ‘
SW-1
’.
The above figure shows the DYNAMIX DH - 114 Mswitch ‘
SW-1
’ has been assigned to domain ‘
TEST
’
successfully.
NOTE:
The detail property window is different for DYNAMIX DH - 114.
Access Switch via Remote Configuration
Only DYNAMIX DH - 114 M (contains RMU) supports the capability of remote configuration. The configuration
utility communicates with your remote switch system by ‘Telnet’ protocol at port number ‘8861’. Make sure your
PC supports ‘TCP/IP’ before you start the remote configuration.
1. Execute the configuration utility on PC, choose ‘
Internet
’ in the field ‘Connection Type’. Login the correct
domain, as ‘
TEST
’ for example. The ‘Connection Type’ in the bottom of next figure denotes ‘
Internet
’ instead
of ‘
COM1
’ for remote configuration. Note that we just login and browse the connection topology within the
domain, we don't make any connection to the switch ‘
SW-1
’ yet.
2. The factory default IP address is ‘
192.168.0.1
’ and default subnet mask is ‘
255.255.255.0
’ for the RMU if
there is no DHCP Server. To access the switch with default IP, your PC should be within the same IP network
as the switch DYNAMIX DH - 114 M. That is, your PC's IP address should be as "192.168.0.xxx". For
instance, you may connect one PC with the switch directly by one Ethernet cable between your PC's Ethernet
adapter and switch's E1 port. And configures your PC's TCP/IP setting to fixed IP as "192.168.0.xxx", subnet
mask as "255.255.255.0", disable DHCP option. Reboot your PC to access the switch via the configuration
utility within the same "192.168.0.xxx" network.
3. Double click on ‘
SW-1
’ icon will try to login and connect the switch in our example.