Dynamix DC – 16 S/SA 16 ports SHDSL DSLAM modem/router
User Manual
Step 2: Prepare an new SHDSL software (filename, IP24s_TFTP_
V243_NoBrand.BIN, is taken as an example here ) and the TFTP utility.
Step 3: Extract the TFTP utility, “tftp.zip”, into one directory of your PC.
Step 4: Rename the filename “IP24s_TFTP_ V243_NoBrand.BIN” as “shdsl”
and put into the same directory with TFTP.
Step 5: Log in CLI by using a RS-232 cable and type the command” sysip” to
access the IP address of Dynamix DC-16S/SA. (this step can be skipped if
the IP address of Dynamix DC-16S/SA has been available).
Step 6: Activate the “MS-DOS mode” and enter the directory that you made for
TFTP utility.
Step 7: Key in the following command to upgrade your Dynamix DC-16S/SA:
C:\TFTP\tftputil 192.168.100.111 put shdsl
C:\TFTP \tftputil 192.168.100.111 put shdsl
Transfer successful: 8 bytes in 1 second, 8 byte/s
Transfer successful: 2097152 bytes in 91 seconds, 23045 byte/s
C:\TFTP\tftputil
C:\TFTP\tftputil
Step 8: After entering this command, Dynamix DC-16S/SA will be
upgraded immediately. When Dynamix DC-16S/SA is upgrading, LED,
“MAINT”
“ALARM” and “FAULT”, will be blinked. It takes 20 seconds to complete
upgrade if there is no power off during the procedure.
Step 9: Once those 3 LEDs stop blinking, the software upgrade is completed
and Dynamix DC-16S/SA will restart automatically.
Step 10: Enter Dynamix DC-16S/SA CLI again and type the command,
“show sysinfo” to verify the software version. The version shall be “2.43”
You cannot access the Dynamix DC- 16S via the console port
Check if the Dynamix DC-16S/SA is connected to
your computer’s serial port.
Check if the communication program is configured
correctly.
If the problem remains unsolved, contact for technical
support.