Dynamite Ultra AC/DC Charger/Cycler
www.DynamiteRC.com 7
Key Beep ON
Music 01
10. a) Set Operating Beep Sound (On/Off) or
b) Select Music
Volume Adjust
100%
11. Adjust Volume
Input Volt Low
Cut Off 11.0V
12. Set Detecting Input Low Voltage
Back Light
Brightness 100%
13. Adjust Background Brightness
Load Default
YES/NO ?
14. To reset the charger to Initial Setting
ni-Mh and ni-Cd Charge Mode
NiMH Charge
4.0A
Message during ni-Mh Charging
While in the User Setup mode, press the dial to
change to Ni-MH battery charging. Press the dial
again to confirm changes.
NiMH 000 : 01 : 0001
Chg 0.10A 7.62V
See the status by turning switch to left/right.
Press the MODE button to adjust the charge
current. Press the START dial and adjust the
current rate to the appropriate rating.
Press and hold the dial for 3 seconds to activate
charge. The charge status and other settings
can be monitored by rotating the dial during fast
charge.
NiMH Sensitivity
D.Peak 3mV/Cell
1. Ni-MH Charge Sensitivity
To reset to factory recommended sensitivity,
see Load Default and select “Yes.”
Peak Voltage
9.07V
2. Battery Pack Peak Voltage