Dynamite Ultra AC/DC Charger/Cycler
www.DynamiteRC.com 15
Select Voltage
10.8V
1. Selected Discharge Voltage Cutoff
The discharge cutoff voltage value is
predetermined when selecting 1.8V, 5.4V, or
10.8V setting for the corresponding 2V, 6V,
or 12V battery being discharged and is not
selectable during discharge.
Input 13.01V
System Temp 36°C
2. Input Voltage/System Temperature
warning information
1. If the battery connection is lost during
operation, the OPEN/STOP error will flash.
Reconnect battery or replace.
2. Low Input Volt: Power input is below
minimum requirements. Increase source
power voltage.
3. Reverse Polarity: Battery polarity reversed
4. Waiting Overheating: Charger temperature
overheated. Lower charge/discharge
current rates and be sure the cooling fan is
unobstructed.
5. After discharging, Ni-MH/END will flash
alternately.
6. When the charge reaches the negative delta
voltage, the Ni-MH/FULL is displayed.
7. When the charge reaches the Timed setting
limit, the Ni-MH/TIME is displayed.
8. When the charge reaches the capacity
setting limit, the Ni-MH/CAPA is displayed,
Ni-MH/CAPA will flash alternately.
9. When the charge reaches the Temperature
setting limit, the Ni-MH/TEMP is displayed.
10. Li-Po/Li-Fe Battery Low Voltage, LOW/VOL
will flash alternately.
11. Cooling fan is not working, FAN/STOP will
flash alternately.
System Err
Return to Repair
12. Charger Breakdown
Current Err
Return to Repair
13. Charger Breakdown