background image

VELOCITY 13µ 

Minifuge 

Operation Manual 

Model Velocity 13µ 

Revision : D01- V1.

01

 

Содержание VELOCITY 13u

Страница 1: ...VELOCITY 13µ Minifuge Operation Manual Model Velocity 13µ Revision D01 V1 01 ...

Страница 2: ......

Страница 3: ... on off 7 3 2 Rotor coupling and disassembling 8 3 3 Positioning of Sample Tubes 9 4 Operation 10 4 1 Key Functions of Control Panel 10 4 2 Setting RPM RCF 11 4 3 Setting Time 12 4 4 Start Stop 12 4 5 Pulse 13 4 6 Emergency door open 13 5 Maintenance 14 5 1 Outer part of instrument 14 5 2 Chamber 14 5 3 Shaft 14 5 4 Rotor 14 5 5 Transportation of the instrument 14 6 Trouble Shooting 14 6 1 Check l...

Страница 4: ...ng for rotor coupling Attention and warning for door opening and closing 1 1 2 Symbols in this document Symbol Meaning Symbol Meaning This symbol refers to safety relevant warnings and indicates possible dangerous outcomes Note This symbol refers to the important reminder 1 2 Safety Precautions Before using the instrument please read this operation manual to ensure correct usage through understand...

Страница 5: ...t properly check it with spinning manually 8 Do not stop the rotor by touching with hand during the instrument is running 9 Emergency door open should be performed only when spinning is completely stopped 10 Should not exceed the rated speed or specific gravity Samples whose density is greater than 1 2g ml must have reduced maximum rotational speed to avoid rotor failure 11 The sample content shou...

Страница 6: ...o recommended by IEC 61010 2 020 9 Use the emergency door open function only when the door button on the control panel is dumb under the condition of complete stop of rotor running 9 Never try to open or move the instrument if it is not completely stopped 9 If the power input is more than 10 of the recommended voltage or fluctuates frequently it may cause malfunction of the instrument and often re...

Страница 7: ...oduct Description Technical Specifications 2 1 Product Description Velocity 13μ includes Fixed Angle rotor FA13A and 12 of 0 2ml 0 5ml adaptors The PCR tube rotor is optional Emergency Door open Power supply ...

Страница 8: ... 4 x 8 tube PCR strips Time control Pulse or timed 30 min RPM RCF conversion Yes Noise level dB 56 Acc Dec sec 12 16 Display Blue LCD Automatic door release at completion Yes Power supply V Hz 220 50 60 110V optional Power requirement VA 110 Watts Dimension W x D x H mm 208 x 245 x 145 Weight without rotor Kg 4 4 CE mark Yes ...

Страница 9: ...or close it until hearing clank shut 9 The door is not opened while the instrument is running 9 If the door is opened the instrument could not operate even with pressing the Start button 9 Power Failure If there is any power failure during the operation door is not opened with Door button Door can be opened only when the operation is completely stopped and the power is on again If you want to open...

Страница 10: ...ocking Nut clockwise until tightly assembled To disassemble the rotor Rotate the Rotor Locking Nut counterclockwise 9 When the PCR rotor is coupled please do not speed over 6 000rpm 2 400 rcf 3 3 Positioning of Sample Tubes Action 1 Before loading sample tubes check the water drop or dirt in the rotor hole or inner adaptor If there is a water drop or dirt in the rotor hole or inner adaptor remove ...

Страница 11: ...ys of Sample Balancing Tube usage If the number of samples is not in pair please load the control tubes at each symmetrical position Otherwise it results noise and vibration which eventually damages the instrument ...

Страница 12: ...played as rpm and rcf While running is flickering appears when the Door is opened and appears when the Door is closed Time is displayed as min Setting Buttons When setting up the RPM RCF and Time you can put the set value with up and down button Function Buttons Door For opening instrument door Pulse For quick spin down Start Stop Commend start and stop operation ...

Страница 13: ...value press RPM RCF button If you do not press the button for 5 second the setting mode is cleared 1 Press a RPM RCF button twice RCF MODE is generated by pressing a RPM RCF button twice RCF LED is flickering on the display window 2 Press the buttons to change input value RCF setting unit 0 1 unit 0 1 100 rcf After 5 seconds from pressing the input value the setting value is saved If you want to c...

Страница 14: ...or is closed In case of pressing the Start Stop button while running the running is stopped 4 5 Pulse It is for quick spin down Action 1 If you press Pulse button and release at the point you want to stop the centrifuge decelerates immediately When the running is stopped the door is opened automatically with beeping sound 4 6 Emergency Door Open The door can be unlocked manually with Emergency Doo...

Страница 15: ...ent and clean contaminated area 5 3 Shaft 1 Always make special attention to clean the motor shaft to avoid any imbalance problem due to the contaminants 2 After using the instrument take out the rotor from the shaft and clean the shaft with dry soft cloth to keep dry 5 4 Rotor 1 If any parts are contaminated with samples clean the rotor with soft wet cloth and keep the rotor dry 2 Be careful not ...

Страница 16: ...t can t run Check the Door LED on the display window and close the door completely Can t open the door If the power is out check the main fuse for the laboratory to supply the power If it is not solved in shortly open the door with spikes for safety of sample Please refer to 4 6 Emergency Door Open Can t close the door Remove the dirt at the door latch and then close the door completely again If t...

Страница 17: ...pen the door with emergency door tool manually for safety of sample Please refer to 4 6 Emergency Door Open Error 3 Motor Overheating If the motor is overheated this message is appeared Shut off the power supply for an hour and then turn on the power switch for checking the instrument If the error code shows continuously please contact us Error 4 Low Voltage If the power input of Power supply V Hz...

Страница 18: ...irmware Download Error 8 Imbalance Check weight balances of samples Please refer to 3 3 Positioning of Sample Tubes and then turn off and on the instrument for checking Any wire disconnection or tuning of the instrument must be performed only by a service engineer who is authorized by Dynamica ...

Страница 19: ...17 7 Rotors and Accessories ...

Страница 20: ...eu com Australasia Dynamica Pty Ltd Unit C3 Hallmarc Business Park Corner Centre and Westall Roads Clayton Victoria 3168 Australia P 61 3 8540 5988 F 61 3 9548 7177 Email info dynamica com au Asia Dynamica Asia Limited 6 F Mita Centre 552 566 Castle Peak Road Kowloon Hong Kong P 852 2754 9488 F 852 2751 9477 Email info dynamica asia com Web www dynamica eu com ...

Отзывы: