4.1 Setting DIP switches
4.1.1 Setting optional DIP switches
TERMINATION REGISTER (DIP SWITCH No. 1)
: This switch allows the end of
register to turn on the only last camera of the data lines. If data lines are distributed to
several directions, it has to be switched on such camera among the most far away
cameras. It switched off from factory defaults. (Refer to part c of the figure 8)
RS485 / RS422 SELECT (DIP SWITCH No. 2)
: Select switch on / off so that the data
type is to be proper to your actual using by
RS485
or
RS422
. The default setting is
RS485 mode. (Refer to part c of the figure 8)
ADDR / INIT SELECT (DIP SWITCH No. 3)
: This switch allows set up the
communication baud rate, it sets to be proper data baud rate to be transferred from
controller. In switch off, it is to become 9600 bps and to become 4800 bps in switch
on. Power off and on so that changed speed is applied. The Default setting is 9600
bps. (Refer to part c of the figure 8)
NTSC / PAL SELECT (DIP SWITCH No. 4)
: As a converting switch NTSC system to
PAL system, this switch cannot be changed by user due to the setting up a fix in the
mill. Please do not change. If you want to change the switch, please check model of
this product which is a NTSC or PAL. (Refer to part c of the figure 8)
EXT / INT (DIP SWITCH No. 5)
: The EXT switch is AC Line-Lock and the INT switch
is internal sync. If you want to use the unit in the AC line-Lock, switch to EXT, the
default is EXT (Refer to part c of the figure 8).
TURN ON/OFF SWITCH
: To start the speed dome camera, turn on the switch. If in
reverse, turn off the switch. (Refer to part a of the figure 8)
4. HOW TO USE FUNCTIONAL DIP SWITCHES
Figure 8. DIP SIWTCH PANNEL ON THE DOME DRIVE
NOTE: Please you have to set up the DIP switches in turn off the power then finish the set
up, turn on the power
.
When you set the DIP switch,
please set the DIP switch condition
of power off firstly then turn on the
power. Part A is a power switch.
This part can be set up the address
of each camera. You can set up the
number of camera on the condition
of ADDR in Part C.
In
'
INIT
'
of the part C, you can select
protocols and communication baud
rate.
Please refer to the next page
It is to notice whether power on
and data signal in normal. In power
on, the Green LED is lit and on
operating, the Green LED is lit at
the same time the Red LED is
flickered.