The following steps are the setting to 4800 bps:
Turn off the power on the dome.
DIP SW (INIT
ADDR) must be switched to
'
INIT
'
first.
DIP SW 8 is on.
Turn on the power to initialize 4800 bps.
Turn off the power after initializing baud rate and switch from
'
INIT
'
to
'
ADDR
'
and
DIP SW 8 is off.
Turn on the power again. Now it is on 4800 bps.
The following steps are the setting to 9600 bps:
Turn off the power on the dome.
DIP SW (INIT
ADDR) must be switched to
'
INIT
'
first.
DIP SW 7 & 8 is off.
Turn on the power to initialize 9600 bps.
Turn off the power after initializing baud rate and switch from
'
INIT
'
to
'
ADDR
'
.
Turn on the power again. Now it is on 9600 bps. (9600 bps is default baud rate
from factory.)
4.1.4 Setting protocols with DIP switches
It allows user to operate this dome with various command protocols. It can be
programmed with DIP switches.
To program the protocol, it must be turned off the power first.
The following steps are the setting protocol:
Turn off the power on the dome.
Turn off all DIP switches for address in 8-PIN DIP switches.
DIP SW (INIT
ADDR) in 5-PIN DIP switches must be switched to
'
INIT
'
first.
Switch on the each DIP SW as desire. Refer to the above table for protocol as
desire.
Turn on the power for initializing the protocol.
Turn off the power after initializing the protocol.
Reposition all DIP switches such as protocol programming before. (DIP SW
'
INIT
'
is
switched to
'
ADDR
'
also)
Set up address switches for this camera as desire.
Turn on the power again.
Now it can be operated on desired protocol.
The default is D-MAX protocol, 9600 bps.
1
2
3
4
5
6
7
8
ADDRESS
O
N
4
2
2
I
N
I
T
P
A
L
I
N
T
T
M
4
8
5
A
D
D
R
N
T
S
C
E
X
T
ON
OFF
O
F
F
ON
S1
S2
PROTOCOL
S1
S2
SW1
SW2
SW 7
SW8
SW 'INIT
ADDR'
D-MAX (9600 bps)
OFF
OFF
OFF
OFF
INIT
PELCO-P (9600 bps)
ON
OFF
OFF
OFF
INIT
PELCO-P (4800 bps)
ON
OFF
OFF
ON
INIT
PELCO-P (2400 bps)
ON
OFF
ON
OFF
INIT
PELCO-D (4800 bps)
OFF
ON
OFF
ON
INIT
PELCO-D (2400 bps)
OFF
ON
ON
OFF
INIT