![Dynamic DX-REMG91 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/dynamic/dx-remg91/dx-remg91_installation-manual_2548051064.webp)
GBK63648
:
Issue 3
– February 2012
58
4
Right (M2)
Motor Fault
C: The connection from the PM right (M2)
connector to its associated motor, or the motor
itself, is defective. The connection is either
open or short circuit.
A:
Disconnect the left motor plug & check
continuity between the motor pins on M2
.
A:
Ensure there is no continuity between motor &
park brake terminals
.
5
Left (M1) Park
Brake Fault
C: The M1 plug connection to its associated Park
brake is either open or short circuit.
A:
Disconnect M1 plug & check continuity
between the 2 Positronic park brake pins
.
A:
Ensure there is no continuity between motor &
park brake terminals
.
6
Right (M2)
Park Brake
Fault
C: The M2 plug connection to its associated Park
brake is either open or short circuit.
A:
Disconnect M2 plug & check continuity
between the 2 Positronic park brake pins
.
A:
Ensure there is no continuity between motor &
park brake terminals
.
7
Low Battery
Fault
C: The battery charge is not sufficient to allow
safe driving. It has fallen below 17V.
A:
Check battery connection & terminals. The
battery voltage should be similar when then
battery is on charge, and when it isn‟t
.
A:
Check that fuses have not blown, or circuit
breakers tripped
.
A:
Replace battery if worn out or if capacity is
insufficient for the user‟s needs
.
8
Over Voltage
Fault
C: The battery voltage has exceeded 32V.
A:
If this fault occurs during battery charging, the
battery charger is defective or incorrectly
adjusted
.
A:
Check the battery chargers open circuit
voltage is in accordance with the battery
manufacturers limits, and is less than 32V
.
C: The battery connector is making intermittent
contact when the wheelchair is stopped, or
travelling down a slope.
A:
Check that the battery wiring and terminating is
secure
.
Содержание DX-REMG91
Страница 1: ......
Страница 2: ......
Страница 6: ...GBK64048 Issue 3 February 2012 ...
Страница 8: ...GBK63648 Issue 3 February 2012 2 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Страница 10: ...GBK63648 Issue 3 February 2012 4 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Страница 33: ...Chapter 3 G91 Operation 27 3 9 1 Joystick Only Menu Map ...
Страница 40: ...GBK63648 Issue 3 February 2012 34 Pattern 3 1 2 1 3 1 4 Pattern 4 1 5 1 6 1 2 1 3 1 4 ...
Страница 45: ...Chapter 4 G91S Operation 39 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Страница 51: ...Chapter 5 Installation and Testing 45 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Страница 61: ...Chapter 6 Programming G91 55 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Страница 69: ...Chapter 9 Appendices 63 8 3 External Dimensions All dimensions in mm ...
Страница 79: ...Chapter 9 Appendices 73 ...