Page 7
3101C-TJ101 MANUAL
06/14
MODEL 3101C-TJ101
DELAY EGRESS SYSTEM
WIRING INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
The external 7050 is included with the 3101C-TJ101 to provide reset and bypass functions to the maglock using the
7050’s momentary / maintained key switch. The external 7050 also indicates lock status as well as door movement during
egress sensor adjustment through LED 1 located on the 7050 faceplate.
The 3101C-TJ101 circuit board is supplied with flying lead connections for LED 1 and the 7050 key switch. These leads
must be connected to match the same color flying leads coming from the 7050-LED.
(See above illustration
).
Remember to observe polarity for either the key switch or LED’s three wire harness. The key switch must be connected
with the blue wire facing the left
(WHITE/BLACK/BLUE See above illustration)
. The LED 1 must be connected with the
green wire facing the left
(GREEN/BLACK/RED See above illustration)
.
EXTERNAL MODEL 7050xLED KEY SWITCH CONNECTIONS