3101C-TJ101 MANUAL

06/14

MODEL 3101C-TJ101

DELAY EGRESS SYSTEM

WIRING  INSTRUCTIONS

705 Emmett Street    Bristol, CT 06010

 1-877-DynaLock    www.dynalock.com

OPTION WIRING

MONITORING OUTPUT DESCRIPTIONS

DELAY EGRESS OUTPUT

Delay egress alarm monitoring.

SPDT dry relay contacts rated 1Amp @ 24 Volts

Contacts change state upon initiation of delayed 

egress, after the nuisance delay has elapsed.  

They remain in that state until door is closed and 

reset.

DYNST OPTION OUTPUT

Dynastat bond sensor monitoring.

SPDT dry relay contacts rated 1Amp @ 24 Volts

Contacts change state to signal lock status as 

either secure or unsecure.  Armature misalignment 

can also create an unsecure condition. 

DSM OPTION OUTPUT

Door position sensor monitoring.

SPDT dry relay contacts rated 0.5Amp @ 24 Volts

Contacts change state to signal physical door 

position as either closed or open.  DSM is an  

independent circuit that does not require lock 

power to operate.

ATS OPTION OUTPUT

Anti-Tamper Switch monitoring. 

SPDT dry relay contacts rated 0.5Amp @ 24 Volts

Contacts change state to signal removal of the 

lock electronics cover.

TYPICAL WIRING

NOTE: INDICATORS ARE NOT INCLUDED

NOTE: INDICATORS ARE NOT INCLUDED

NOTE: INDICATORS ARE NOT INCLUDED

NOTE: INDICATORS ARE NOT INCLUDED

13 14 15

ALARM

SECURE

NC C NO

TO INDICATOR

POWER SUPPLY

16 17 18

UNSECURE

SECURE

NC C NO

TO INDICATOR

POWER SUPPLY

19 20 21

OPEN

CLOSED

NC C NO

TO INDICATOR

POWER SUPPLY

22 23 24

TAMPER

NORMAL

NC C NO

TO INDICATOR

POWER SUPPLY

E

F

G

H

Содержание 3101C-TJ101

Страница 1: ...MODEL 3101C TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS 705 Emmett Street Bristol CT 06010 1 877 DynaLock www dynalock com ...

Страница 2: ...T UP Remove the Electronics Cover to expose the circuit board assembly 1 2 System Selector Switches The selector switches S3 which control major system functions are factory set to the OFF position for basic lock operation Switch 1 will be used during sensor adjustment page 8 Switches 2 through 7 are only used for options described on page 10 L C C Factory Setting ...

Страница 3: ... 10 SEE PAGE 11 Terminals 3 4 Fire Panel Input May be normally open N O or normally closed N C dry contacts from fire panel check fire alarm control jumper FA page 6 DO NOT APPLY POWER TO TERMINALS 3 4 OR CIRCUIT BOARD DAMAGE WILL OCCUR When the fire panel trips the 3101C TJ101 will release the audible will sound a constant tone and the bi color LED LED1 will change to green When the fire panel is...

Страница 4: ...ion later With the door closed observe the bi color LED LED1 on the circuit board It should be lit red If it is not lit rotate the adjustment wheel counter clockwise as necessary to ensure that it will contact and fully depress the ball plunger on the lock Rattle the door to ensure the LED remains lit With the door closed and LED1 lit red unlatch and slowly open the door The LED will shut off as s...

Страница 5: ... AUDIBLE SIGNAL LOCK 7050 LED DELAY EGRESS ALARM One second pulse rate during delay cycle ON BLINK RED DELAY EGRESS ALARM Steady tone after delay until reset OFF GREEN FIRE ALARM RELEASE Steady tone until fire alarm contacts are reset OFF GREEN OPTIONAL REMOTE AUTHORIZED BYPASS TERMINALS 7 8 9 10 None unless bypass audible is enabled dip switch 2 If door is held open past relock time goes into del...

Страница 6: ...dress your specific system requirements The normal factory setting is all switches off 1 C 1 SYSTEM SET UP NORMAL SET UP MODE 2 BYPASS AUDIBLE DISABLED ENABLED 3 NUISANCE DELAY 1 SEC 3 SEC 4 EGRESS DELAY 15 SEC 30 SEC 5 MASTER AUDIBLE ENABLED DISABLED 6 7 EGRESS SENSOR ENABLED DISABLED 8 UNUSED SPARE SWITCH FUNCTION OFF ON MODE SETTINGS Only applies to terminals 9 10 see next page FIRE ALARM INPUT...

Страница 7: ...ment through LED 1 located on the 7050 faceplate The 3101C TJ101 circuit board is supplied with flying lead connections for LED 1 and the 7050 key switch These leads must be connected to match the same color flying leads coming from the 7050 LED See above illustration Remember to observe polarity for either the key switch or LED s three wire harness The key switch must be connected with the blue w...

Страница 8: ... sensor initiation is not desired see page 10 note 3 INPUT DESCRIPTIONS WARNING Do not apply power to inputs marked or damage will occur A C B D REMOTE BYPASS INPUT TIME DELAY Momentarily closing a normally open dry contact across terminals 9 10 will immediately release the lock without alarm The door will remain unlocked for a period of time controlled by on board adjustable timer S2 To increase ...

Страница 9: ...nt can also create an unsecure condition DSM OPTION OUTPUT Door position sensor monitoring SPDT dry relay contacts rated 0 5Amp 24 Volts Contacts change state to signal physical door position as either closed or open DSM is an independent circuit that does not require lock power to operate ATS OPTION OUTPUT Anti Tamper Switch monitoring SPDT dry relay contacts rated 0 5Amp 24 Volts Contacts change...

Страница 10: ...COND COIL HARNESS 4 COND DSM OPTION SENSOR LOCK COIL ASSEMBLY 3101C TJ101 CIRCUIT BOARD Harness connectors J3 and J6 are not polarity sensitive Harnesses J6 and J8 are only present if the 3101C TJ101 is equipped with the DYN Dynastat Force Sensor and or DSM Door Status Switch Options Observe polarity when re connecting the J5 and J8 harness connectors Orient these connectors with respect to harnes...

Страница 11: ...Page 11 3101C TJ101 MANUAL 06 14 MODEL 3101C TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS 705 Emmett Street Bristol CT 06010 1 877 DynaLock www dynalock com INSTALLER NOTES ...

Страница 12: ...UPON COMPLETION OF THE 3101C TJ101 INSTALLATION FOR PRODUCT SUPPORT AND PARTS ORDERING INFORMATION CONTACT DynaLock Corp 705 Emmett Street Bristol CT 06010 Bus 877 396 2562 Toll Free USA 860 582 4761 Fax 860 585 0338 DYNALOCK ON THE INTERNET E mail info dynalock com Website www dynalock com ...

Отзывы: