background image

Page 8

2280 MANUAL - FORM 2280-001

MODEL 2280 SINGLE/OUTSWING

ELECTROMAGNETIC LOCK

INSTALLATION  INSTRUCTIONS

4/07

705 Emmett Street    Bristol, CT 06010

 1-877-DynaLock    www.dynalock.com

UL

C

R

US

LISTED

PLEASE DELIVER THIS MANUAL

 TO THE END-USER UPON COMPLETION

OF THE INSTALLATION

GWXT Auxiliary Lock

FOR PRODUCT SUPPORT AND PARTS
ORDERING INFORMATION CONTACT:

DynaLock Corp.
705 Emmett Street
Bristol, CT  06010
Bus: (877) DYNALOCK, Toll-Free USA
        (860) 582-4761
Fax: (860) 585-0338

DYNALOCK ON THE INTERNET:

E-mail: [email protected]
Website: www.dynalock.com

CSFM

NYC Mea #23-92-E

THE FOLLOWING LISTINGS ARE PENDING

Содержание 2280

Страница 1: ...er obstruction which may interfere with the lock and armature making good contact These faces may be cleaned with a non abrasive pad and wiped with an oil dampened cloth Familiarize yourself with the door and frame conditions The lock must mount rigidly to the under side of the door frame header The door mounted armature is supplied with hardware that allows it to pivot slightly to compensate for ...

Страница 2: ...EL 2280 BILL OF MATERIALS 1 2280 LOCK ASSEMBLY 1 ARMATURE 1 ARMATURE HOUSING 1 HARDWARE KIT 1 MOUNTING TEMPLATE 1 INSTALLATION MANUAL 1 WIRING MANUAL QTY ITEM DESCRIPTION 7 Baseplate Mounting Screws 10x1 phillips pan head sheet metal screw 7 Baseplate Mounting Screws 10 24x1 2 phillips pan head machine screw 1 Armature Mounting Screw 5 16 18x2 hex at head machine screw turned 4 Armature Housing Sc...

Страница 3: ...om the push side place the template against the header and door with one edge against the vertical strike jamb and tape in place Transfer all hole locations to both the door and header with a center punch then remove the template from the door Referring to the template drill two 1 8 dia lock mounting holes or tap for 10 24 and one 9 16 dia wiring hole in the top of the frame at the transferred loc...

Страница 4: ...cure the Armature to the door could result in serious injury or possible security breach From the three illustrations below select the one that resembles your door type and follow the instructions for drilling the Armature Mounting Screw hole See Template Drill four 4 1 8 dia holes for 8 x 1 sheet metal screws or drill and tap for 8 32 x 3 8 machine screws See Template GLASS AND ALUMINUM OR HOLLOW...

Страница 5: ...the remaining 5 screws into the header using the baseplate as a physical template Screw heads must not project above the baseplate ARMATURE AND LOCK FACE MUST MAKE FULL CONTACT MAGLOCK SHOULD BE PARALLEL HEADER 3 Attach the Lock to the Baseplate With the 3 16 Hex wrench permanently fasten the lock to the Baseplate with the two 1 4 20 x 1 1 4 ma chine screws removed earlier BASEPLATE 1 Mount the Ba...

Страница 6: ...SWING ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS 4 07 705 Emmett Street Bristol CT 06010 1 877 DynaLock www dynalock com EXPLODED PARTS VIEW LEGEND ON NEXT PAGE 12 3 4 1 13 16 1 1 2 7 3 8 2 3 8 10 2 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 1 4 11 16 1 2 17 ...

Страница 7: ...crew 3 Lock Housing 301297 4 Access Cover 301296 5 8 32x3 8 Machine Screw 300608 6 Anti Tamper Plug 7 1 4 20x1 1 4 Socket Head Screw 300603 8 5 16 18x2 Arm Screw Turned 9 Armature 300968 ITEM DESCRIPTION PART 10 8x1 Self Tapping Screw 10 8 32x3 8 Machine Screw 11 Armature Housing 301245 12 0 360 L Armature Spacer 14 Steel Washer 15 Door Spacer Tube 16 Sex Nut 17 Disc Magnet DSM only 301289 PARTS L...

Страница 8: ...PLEASE DELIVER THIS MANUAL TO THE END USER UPON COMPLETION OF THE INSTALLATION GWXT Auxiliary Lock FOR PRODUCT SUPPORT AND PARTS ORDERING INFORMATION CONTACT DynaLock Corp 705 Emmett Street Bristol CT 06010 Bus 877 DYNALOCK Toll Free USA 860 582 4761 Fax 860 585 0338 DYNALOCK ON THE INTERNET E mail info dynalock com Website www dynalock com CSFM NYC Mea 23 92 E THE FOLLOWING LISTINGS ARE PENDING ...