2280 MANUAL - FORM 2280-001
MODEL 2280 SINGLE/OUTSWING
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
4/07
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Inspect the door frame and determine if an angle bracket, ller or spacer plate will be required for installation.
Note:
Remember to leave space so that the door hits the stop
the maglock, to prevent loosening over time.
MOUNTING CONSIDERATIONS
USING THE TEMPLATE
Fold the template on the dotted line to form a 90 degree
angle. Scoring the template with a straight edge and a
screwdriver will make it fold easier.
With the door in the closed and latched position, from
the push side, place the template against the header
and door with one edge against the vertical strike jamb
and tape in place.
Transfer all hole locations to both the door and header
with a center punch, then remove the template from
the door.
Referring to the template drill two 1/8” dia. lock
mounting holes (or tap for 10-24) and one 9/16” dia.
wiring hole in the top of the frame, at the transferred
locations. Remaining mounting holes will be drilled
after lock is rst mounted and adjusted (page 5).
1.
2.
3.
4.
Drill the remaining transferred holes in the face of the door to accept the Armature, following the instructions
on page 4 for your speci c door type.
5.
*See Price Book or visit www.dynalock.com - 4000 Series Mounting Accessories
NORMAL
MOUNTING
FILLER PLATE
REQUIRED*
SPACER PLATE
REQUIRED*
ANGLE BRACKET
REQUIRED*
2-3/8”
2-3/8”
2-1/8”
2-1/8”
1/2”