MOUNTING THE ARMATURE
Mount the Armature Housing to the door using four (4) #8 x 1” sheet metal screws or #8-32 x 3/8” machine
screws.
Place the Armature inside the Armature Housing and secure using the proper hardware, according to the above
illustrations. Firmly tighten the Armature mounting screw with a 3/16” hex wrench.
Failure to properly secure the Armature to the door could result in serious injury or possible security
breach.
From the three illustrations below, select the one that resembles your door type and follow the instructions for drilling
the Armature Mounting Screw hole. (See Template)
Drill four (4) 1/8” dia. holes for #8 x 1” sheet metal screws or drill and tap for #8-32 x 3/8” machine screws (See
Template).
GLASS AND ALUMINUM
OR HOLLOW METAL DOOR
SOLID CORE DOOR
REINFORCED DOOR
Drill an 11/32” diameter hole
through the door. From the
sex nut side only enlarge the
hole to 21/32” diameter.
Drill an 11/32” diameter hole
through the door. From the
sex nut side drill 1/2” diameter
hole to 1” depth.
Drill a 17/64” diameter hole
and tap for 5/16-18 thread
1/4” MIN