PRE-GONG
It is possible to program a pre-chime signal that is heard before an announcement.
The pre-chime signal is transmitted into the selected areas when activating the
return_k input. You can begin with your announcement during the transmission of
the pre-chime signal; you can talk "through" the pre-chime. Activating the return_k
input opens the
Pre-Gong
dialog box where the current state of the chime („on” or
„off”) is indicated. Activate the u p _ k or down_k input to activate/deactivate the
pre-chime. Activating the return_k input stores the setting
and returns to the user menu.
BUZZER
The speaker output contacts can be programmed as acoustic alert signal. A
speaker must be connected to the speaker output contacts before a sound can be
heard. There is no integrated speaker on board. During failure, malfunction, or as
general alert a buzzing sound is heard. When an alarm has been launched, the
buzzing can be heard for the whole period of the alarm.
Activating the return_k input opens the
Buzzer
dialog box where the current state of
the buzzer („on” or „off”) is indicated. Activate the up_k or the down_k to activate/
deactivate the pre-chime. Activating the return_k input stores the setting and
returns to the user menu.
HINT: This menu item is only available after entering t h e c o r r e c t password.
DATE / TIME
The connected call station kits allow setting the date and time of the PROMATRIX
8000 system.
Activating the return_k input opens the
Date / Time
dialog box, which allows
selecting
day, month, year, hour, minute or seconds by activating the up_ k o r dow n_ k
inputs.
Edit the parameters by activating the K e y _ 1 t o 1 0 inputs.
Key_s1 corresponds with “0”, Key_s2 with “1” an so on. Up to key_s0 which
corresponds with “9”.
Activating the return_k input stores the setting and returns to the user menu.
LCD CONTRAST
Call station kits with use of a display allow the user to individually adjust LCD
contrast and viewing angle. This allows optimum legibility from the user's
location.
Activating the r e t u r n _ k i n p u t opens the
LCD contrast
dialog box where the
user
can select a contrast setting in the range of 0 % to 100 % by activating the u p _ k
or
down_k inputs.
Activating the r e t u r n _ k i n p u t stores the setting and returns to the user menu.
LCD BRIGHTNESS
Activating the return_k input opens the
LCD brightness
dialog box where the user
can set the display brightness by activating the u p _ k or down_k inputs.
Activating the r e t u r n _ k i n p u t stores the setting and returns to the user menu.