If a call station extension is replaced in a call station system that has already been configured,
the replacement device must be assigned the address of the first device via the DIP switch
EXTENSION ADDRESS.

36

en | Appendix

DPC 8000

 

28-Feb-2013 | |

 

 

Содержание DPC 8000

Страница 1: ...DPC 8000 en ...

Страница 2: ......

Страница 3: ...witch NRS 90231 14 6 Activation 16 6 1 PCA BUS interface 16 6 1 1 Interface description 16 6 2 LINE interface 17 6 3 MIC interface 17 6 4 EXT interface 18 7 Configuration 19 7 1 User menu 21 7 2 Setup menu 22 8 Operation 24 8 1 Indicators 24 8 2 Functions 25 9 Maintenance 29 10 Technical data 30 10 1 Block diagram 31 10 2 Dimensions 32 10 3 Standards 32 11 Appendix 34 11 1 CAN bus basics 34 11 2 C...

Страница 4: ...or Do not disable the safety ground connection function of the supplied power cable If the plug of the supplied cable does not fit your mains socket please contact your electrician 10 Ensure that it is not possible to stand on the mains cable Take precautions to ensure the mains cable cannot become crushed particularly near the device connector and mains plug 11 Only use accessories extensions for...

Страница 5: ...by a trained customer service technician 1 Repair work on the device must comply with the safety standards specified in EN 60065 VDE 0860 2 A mains isolating transformer must be used during any work for which the opened device is connected to and operated with mains voltage 3 The device must be free of any voltage before performing any alterations with upgrade sets switching the mains voltage or p...

Страница 6: ... pop shield and permanent monitoring a total of 20 buttons an illuminated LC display and an integrated loudspeaker The call station can be modified to suit the user s requirements by connecting up to five DPC 8120 call station extensions each with 20 customizable function and speed dial buttons 2 6 en Brief description DPC 8000 28 Feb 2013 ...

Страница 7: ...al microphone or audio source Built in loudspeaker High resolution LC display Comprehensive parameter settings menu on the actual call station Microphone and line monitoring Error message via LED and buzzer and error text in the LC display Processor control of all functions Monitoring of the processor system via watchdog circuit Non volatile FLASH memory for configuration data The call station is ...

Страница 8: ...1 DPC 8120 Call Station Extension 1 6 pin connecting cable for call station extension 1 Connecting holder for call station extension 1 Connecting plate for call station extension 6 Screws self tapping 1 Technical information 1 Warranty card with safety notes Table 4 2 DPC 8120 scope of delivery Warranty For information regarding the warranty see www dynacord com 4 8 en Scope of delivery and warran...

Страница 9: ...Installation Top Figure 5 1 DPC 8015 5 5 1 DPC 8000 Installation en 9 28 Feb 2013 ...

Страница 10: ...ror occurs 5 ALARM LED Illuminates red if an alarm is triggered 6 Microphone Monitored goose neck microphone 7 Loudspeaker Plays back signal sounds 8 Display Status error displays for the call station or the entire PROMATRIX 8000 system 9 ESC button Acknowledges and advances to next error message 10 button Activates the PROMATRIX 8000 system 11 DEL button Selects all zones and groups 12 button Sto...

Страница 11: ...Bottom Figure 5 3 DPC 8015 5 2 DPC 8000 Installation en 11 28 Feb 2013 ...

Страница 12: ...icrophone 5 EXTENSION ADDRESS DIP switch for setting the address of the call station extension Delivery condition The call stations are programmed with the following factory functions and properties settings Parameters Setting description CAN address 0 disconnected Name DPC 8015 Password Setup menu password protected default password 2222 Opening gong Off Buzzer On acoustic warning signal Compress...

Страница 13: ...ng a suitable slotted screwdriver Insert the labeled strip into the open label field and close the label field by evenly pressing down on the cover Retrofit options The DPC 8015 call station can be retrofitted with a maximum of three covered buttons EB DPC item F01U101089 or key switches NRS90231 item F01U101000 Additional control elements can be used for example for triggering alarms in certain a...

Страница 14: ... the button into the installation location and press in evenly it must be possible for the cover cap to open upward 6 Depending on whether the right middle left installation location is used plug the ribbon cable into plug connector CN201 CN202 CN203 on the circuit board 7 Plug the connecting cable into CN1 again 8 Re attach the call station baseplate 9 Re connect the connections 10 Configure the ...

Страница 15: ...over 6 Align the switch and screw tightly in place using the supplied knurled screw 7 The supplied 4 pin cable and the resistances must be connected as shown in the following diagram R2 10k 1 rt 2 gr 3 gr 4 gr CN1 4 CN1 3 CN1 2 CN1 1 3 4 R1 10k Figure 5 7 Connecting NRS 90231 8 Note the connection sequence of the ribbon cable The two external cables 1 red and 4 green must be cut as close to the cu...

Страница 16: ...o connect the DPC 8015 call station with a PROMATRIX 8000 system This is an 8 pin RJ 45 connector that assigns the power supply control interface CAN bus and audio interface The call station must be connected to the respective wall mount socket via the enclosed network cable 3 m The following image shows the assignment of the PCA BUS socket and the corresponding RJ 45 connector i Notice For CAN AU...

Страница 17: ...the LINE interface is interrupted Use as PTT contact input When connecting a PTT microphone to a DPC 8015 the LINE interface is used as input for the PTT contact The PTT function must be set for the call station in IRIS Net during configuration The following diagram shows the corresponding assignment of a stereo jack plug 3 5 mm mini jack PTT Figure 6 5 Assigning the LINE plug as PTT contact input...

Страница 18: ...his socket is primarily used to connect a DPC 8120 call station extension To do so connect the DPC 8120 to the EXT socket of the call station via the connecting cable provided 6 4 18 en Activation DPC 8000 28 Feb 2013 ...

Страница 19: ...ystem can be configured via the built in LC display In this mode certain buttons have a different function than they would in announcement mode The alternative assignment is specified on the lower right of the respective button 1 Press the button keep it held down and press the button at the same time The display switches from announcement mode to menu mode 2 Use the call station buttons to naviga...

Страница 20: ...ation mode Date Time Password LED test Program 1 Program 4 PROGRAM 1 4 Volume 1 Firmware version CAN address CAN baudrate CAN termination SETUP LCD contrast Volume 4 Setup Menu Monitor Vol Figure 7 1 Menu structure 20 en Configuration DPC 8000 28 Feb 2013 ...

Страница 21: ...TRIX 8000 system The assignment remains valid until the selection buttons are pressed repeatedly If the yellow LED of a selection button illuminates the program cannot be assigned to this circuit or group for topological reasons Pressing the button takes the user to the Volume X submenu which is described below Volume X The volume currently set in the program is displayed Pressing the or button se...

Страница 22: ...Pressing the button accepts the contrast setting selected and returns the user to the User menu LCD brightness Pressing the button takes the user to the LCD Brightness dialog box In this dialog box the display brightness can be adjusted by pressing the or button Pressing the button accepts the brightness selected and returns the user to the User menu LED test Pressing the button activates the LED ...

Страница 23: ...the button accepts the setting selected and returns the user to the Setup menu CAN termination Pressing the button takes the user to the CAN Termination dialog box Pressing the or button activates or deactivates the termination on this call station Termination must be activated on the call station that is connected to the end of the CAN bus Please see section CAN bus basics page 34 Pressing the bu...

Страница 24: ...c Off System is switched off standby Illuminated green System is switched on and ready for operation Flashing green System has been switched on and is booting up activation process Off Pressing the button does not do anything the action cannot be stopped Illuminated green Pressing the button ends an event that has already started DEL Off No all call selected Illuminated green All call pre selectio...

Страница 25: ...ws time information operating states user information setup information error messages with precise device module descriptions and so on Status display in the LC display During normal operation in announcement mode the name of the call station line 1 and the date and time line 2 are displayed in the LC display Error display in the LC display If an error occurs in the PROMATRIX 8000 system this is ...

Страница 26: ...ext The precise function can be configured in the IRIS Net software This button is used to scroll down when navigating through the menu DEL This button is used to select all circuits for announcements gong alarm signals speech reproduction or program assignment Pressing the button once selects all circuits and the corresponding LEDs and the DEL LED illuminate Pressing the button again deletes the ...

Страница 27: ...g zone group is not free see section Indicators page 24 Once the selection has been made the call is started by pressing the button Prior to this the LED indicates whether all lines or the call station input are free If individual lines or the input is occupied by a lower priority event the LED flashes slowly An announcement can still be made but this will interrupt another event If individual lin...

Страница 28: ... covered button for the selection alarm must be pressed The button illuminates red during the alarm Now the lines for the next alarm can be selected Pressing the ESC button switches the alarm off again Stopping signals Pressing the button stops a current alarm or gong or cancels speech reproduction The function of the ESC button priority local events etc can be configured in IRIS Net One exception...

Страница 29: ...Maintenance The DPC 8000 does not require any maintenance 9 DPC 8000 Maintenance en 29 28 Feb 2013 ...

Страница 30: ...le zone function key LC display Lighted LC display 122 x 32 pixel External connectors 1 PCA BUS connector Control data Audio Power supply RJ 45 1 audio source line level phone jack 1 microphone input phone jack 1 EXT connector call station extension RJ 12 Operating temperature 5 C to 45 C Product dimensions Width by Height by Depth 200 by 167 by 65 mm without microphone Net weight 0 6 kg Options E...

Страница 31: ...icrophone Ext Mic Limiter I Supervision Low Pass Mic Amp Sym Amp Line Amp Service Connector MOS Relay Line Amp Mixer Pilot Beep Alert Audio RJ 12 Pilot Detect Push Button 2 Push Button 3 Keyboard Microcontroller DC DC CAN BUS Contrast Brightness Display Pilot Tone Pilot Tone RJ 45 LINE IN PTT 6MHz 10 1 DPC 8000 Technical data en 31 28 Feb 2013 ...

Страница 32: ...Dimensions Figure 10 1 DPC 8015 Figure 10 2 DPC 8120 Standards The DPC 8000 CALL STATION meets the following standards version October 2012 EN 54 16 10 2 10 3 32 en Technical data DPC 8000 28 Feb 2013 ...

Страница 33: ... EN 55103 1 EN 55103 2 EN 60945 FCC ICES 003 DPC 8000 Technical data en 33 28 Feb 2013 ...

Страница 34: ...devices a shared earth cable CAN_GND is added to the network cabling see the following diagram In this way it is ensured that all CAN interfaces in the network have the same potential Figure 11 1 CAN bus Call station extension A maximum of five call station extensions type DPC 8120 can be connected to the DPC 8015 call station The DPC 8120 call station extension has 20 customizable function and sp...

Страница 35: ... the connecting plate 1 and connecting holder 2 with 4 and 2 screws respectively 4 Insert connecting cable 3 into the EXT socket of the call station or call station extension the connector will click into place 5 Set a unique address for the call station extension via the DIP switch EXTENSION ADDRESS 4 i Notice When using several call station extensions these must be assigned addresses in ascendin...

Страница 36: ...n extension is replaced in a call station system that has already been configured the replacement device must be assigned the address of the first device via the DIP switch EXTENSION ADDRESS 36 en Appendix DPC 8000 28 Feb 2013 ...

Страница 37: ......

Страница 38: ...EVI Audio GmbH Sachsenring 60 94315 Straubing Germany www dynacord com EVI Audio GmbH 2013 ...

Отзывы: