SS-IT EX CFE can be used to recover into an immersion bath:
•
combustible metal dusts especially when two or more types of dust are
combined together, including aluminum, magnesium, zirconium, and their
commercial alloys, perchlorate powder or other combustible dusts whose
particle size, abrasiveness, and conductivity present an equivalent hazard
•
unspent gun powder, sulphur, heat powder, anode powders or any other
explosive dust.
WARNING:
It is the user’s responsibility to determine the appropriate
liquid (water, oil, etc) to be used to neutralize the recovered
dust.
WARNING:
DO NOT RECOVER ANY HOT EMBERS OR IGNITED DUSTS.
WARNING:
It is the user’s responsibility to conduct a risk assessment in
regard to the compatibility of the dusts recovered and the
flammable gases, vapors or liquids and other combustible
dusts present in the hazardous location.
3.0 COMPRESSED AIR REQUIREMENTS
IMPORTANT:
The compressed air has to be clean, dry and oil free to
prevent blockage of the pneumatic system.
Single Venturi
Minimum diameter of air
supply hose and fittings
0.5" (12.7mm)
Input air pressure for ideal
performance
80 psi (5.5. bars)
Input air volume for ideal
performance
45 cfm (76.5 cu. meters /
hour)
Minimum compressor size
15 hp
IMPORTANT:
Do not downsize the compressed air fittings or air supply line.
Downsizing the fittings will result in a reduction of the vacuum
cleaner’s performance.
IMPORTANT:
Brass (or stainless steel) fittings are required to ensure spark
free operation and to ensure ground continuity between
vacuum cleaner and the compressed air supply.